Quick Operations Owner's manual

4-6 Operation
4. Dispensing Head position controls (Figure 4-4) operate as follows:
! On the X-Y control panel, the arrows pointing to the Left move the Dispensing Head to the
left and the arrows pointing to the Right move it to the right.
! On the X-Y control panel, the arrows pointing Up move the Dispensing Head toward the back
of the dispensing area and the arrows pointing Down move it toward the front of the
dispensing area.
! On the Z control panel, the arrows pointing Up move the Dispensing Head upward and the
arrows pointing Down move it downward.
" NOTE The single arrows and double arrows
move the Dispensing Head different
distances per Mouse click and at different velocities as specified in Table 4-2.
! Clicking on Home sends the Dispensing Head to its “home” position. The home position is
the extreme left front corner of the dispensing area, where the Dispensing Head X, Y, Z-axis
coordinates are set to (0, 0, 0).
Item Description
1 Target Box (click to move dispenser to selected location)
2 Y-axis Controls (forward and back movement)
3 X-axis Controls (side to side movement)
4 Dispenser Radio Button
5 Z-axis Controls (up and down movement)
6 Home Button
Figure 4-4 Dispensing Head Position Controls
1
5
3 6
4
2