Quick Operations Owner's manual
4-4 Operation
Service Shutdown
We recommend that you incorporate the following steps into your service shutdown routine:
1. Perform a Production Shutdown as described in the previous subsection.
2. Turn OFF (0) the Main Power Circuit Breaker at the rear of the system. Lock out and tag out the
power as specified in the Safety section of the Axiom X-1000 Series Operations Manual or the
Axiom X-1000 Series Installation and Service Manual.
3. Verify pressure at the Main Air Inlet is 0 psi.
4. Disconnect the facility air supply hose.
WARNING!
If the facility air hose does not have a quick-disconnect fitting, turn off the facility air
and depressurize the line before disconnecting. Otherwise, injury to personnel may
occur.
5. Disconnect the Main Power cable from the machine or the facility outlet as applicable.
Operation of Dispensing System Controls
Positioning the Conveyor and Dispensing Head
When necessary, an operator can use FmNT position (jog) controls to adjust Conveyor rail width, reposition
the workpiece X-axis location on the Conveyor, and reposition the Dispensing Head in the X, Y, and Z-axes.
These position controls can be operated using the Mouse to click on-screen buttons, or by pressing key
combinations on the Keyboard. Both methods are described below.
" NOTE These procedures assume that the Computer and the dispensing system have been turned
on as specified in the Start-up/Shutdown section.
Using the Mouse
To operate position controls with the Mouse:
1. In the FmNT Main Window, click on Jog.
! The Position Controls dialog box opens. See Figure 4-3.
" NOTE The position controls can be accessed from the Main Window, the Production
Window, the Run Window, the Programming Window, and the Tools Window.
2. Click on the Conveyor 1 radio button to activate the Conveyor position controls or click on the
Dispenser radio button to activate the Dispensing Head position controls.