Quick Operations Owner's manual

Operation 4-3
Shutdown
Emergency Shutdown
WARNING! CAUTION!
In an emergency, failure to completely shut down power to the dispensing system
with the EMO can cause serious injury to the user and damage to the
dispensing system.
During an emergency or malfunction, press the EMO button – the large red button on the Control Panel or on
the back of the dispensing system (see Figure 2-3 in the Safety section for locations). Pressing EMO button
cuts the power to all dispensing system components except the Computer and Monitor and vents all
pneumatic pressure.
For more information on emergency shutdown situations and instructions on restoring system power after an
emergency shutdown, refer to the Safety section.
Production Shutdown (End of Shift)
Depending on your company’s requirements, your X-1000 Series Dispensing System may be left ON or OFF
at the end of a shift. However, we recommend that you incorporate the following procedure into your
production shutdown routine:
1. Wait for the dispensing program to complete.
2. Purge the Dispensing Valve as specified in the applicable Dispensing Valve Installation and
Operation Manual.
3. Save any changes to dispensing programs and then exit FmNT.
4. Press OFF (0) on the Operator’s Console.
5. Verify that all dispensing system motion has stopped.
WARNING!
The Needle Heater and Tooling Plates retain heat for a time after the system has
been shut down. Use extreme caution around these components to prevent burn
injuries.
6. Remove all workpieces from the dispensing chamber.
7. Remove the fluid syringe from the Dispensing Head as specified in the applicable Dispensing
Valve Installation and Operation Manual.
8. Clean the Dispensing Valve as specified in the applicable Dispensing Valve Installation and
Operation Manual.