Quick Operations Owner's manual

3-12 Component Description
Rear View Features Close-up
Below are functional descriptions of X-1000 Series Dispensing System components shown in Figure 3-6.
1. Main Air Gauge
The Main Air Gauge measures the regulated air pressure supplied to all other dispensing system
regulators.
2. Main Circuit Breaker
The Main Circuit Breaker is the main power switch for the dispensing system. It protects the dispensing
system from facility power surges and controls the flow of facility AC power supplied to the Power
Manager. A flange to the right of the Main Circuit Breaker allows it to be locked in the OFF position
during servicing. Switching OFF the Main Circuit Breaker cuts power to all dispensing system electrical
components.
3. Rear Cabinet Door
The Rear Cabinet Door allows access to the electrical, pneumatic, and mechanical components inside.
Because there are high-voltage components inside the cabinet, only trained service technicians should
open this door. Refer to the electrical safety practices and procedures in the Safety section.
4. Main Power Cable
The Main Power Cable connects the dispensing system to the facility AC power source. It attaches to the
Power Manager on the back panel of the dispensing system.
5. SMEMA Connector (downstream)
The downstream SMEMA connector allows for SMEMA communication between the dispensing system
and a downstream machine such as an unloader.
6. SMEMA Connector (upstream)
The upstream SMEMA connector allows for SMEMA communication between the dispensing system and
an upstream machine such as a loader.
7. SECS/GEM Port (Optional)
The SECS/GEM Port allows the dispensing system to communicate with factory management software
running on the facility computer network.
8. Downstream Loader Port
The Downstream Loader Port allows the dispensing system to communicate with a downstream
Free-Standing Loader (FSL) for programming purposes only.
9. Upstream Unloader Port
The Upstream Unloader Port allows the dispensing system to communicate with an upstream
Free-Standing Unloader for programming purposes only.
10. Main Air Filter/Regulator
The Main Air Regulator controls the air pressure supplied to all other system regulators. The regulator
contains a built-in air filter and water trap to ensure that only clean, dry air enters the system. Refer to
Table 4-5 in the Operation section for the recommended pressure setting and other important
information.