Quick Operations Owner's manual
2-8 Safety
Emergency Shutdown Recovery
To recover after an emergency shutdown:
WARNING! CAUTION!
Do not restart the dispensing operation until the condition causing the emergency
shutdown has been alleviated. Failure to comply could cause serious injury to the
user and serious damage to the dispensing system.
" NOTE If the Main Circuit Breaker has been tripped, you will need to switch it back ON (I) and
execute standard startup procedure. Refer to the Operation section.
1. Open the Hatch and clear the Conveyor of all workpieces.
2. Locate and remedy the cause of the emergency shutdown. If necessary, refer to the
Troubleshooting sections of the Axiom X-1000 Series Operations Manual or the Axiom X-1000
Series Installation and Service Manual.
3. Close the Hatch.
4. Turn the red EMO knob counterclockwise until it pops back into position.
5. Press ON (l) on the Operator’s Console.
! FmNT will display a prompt asking if you want to reinitialize or abort the program.
6. Restart the dispensing system as specified in the Operation section.