Emergency Shutdown
Your Axiom X-1000 Series Dispensing System features EMO buttons that the operator or service technician
can use to immediately stop all dispensing operations in case of emergency. This feature helps prevent
injury to personnel and damage to the dispensing system and workpieces being processed.
Your dispensing system design includes two EMO buttons. One EMO button is located on the Operator’s
Console, and the second is located on the rear panel of the dispensing system (see Figure 2-3). The
EMO vents all pressure in the pneumatic system, de-energizes the servo power supply capacitors, and cuts
power to all system components except the Computer and Monitor.
"
NOTE If the operator or technician is unable to reach the EMO button, the Main Circuit Breaker
(Figure 3-6) can be used for emergency shutdown, but doing this will also shut down the
Computer.
Item Description
1 Front EMO Button
2 Rear EMO Button
Figure 2-3 EMO Locations
Emergency Shutdown Situations
As a minimum, activate the EMO in the following situations:
WARNING! CAUTION!
In an emergency, failure to completely shut down power to the dispensing system
with the EMO can cause serious injury to the user and damage to the
dispensing system.
• If anyone is in immediate danger of being injured by moving parts, hazardous materials, or
electrical shock.
• If valuable dispensing system components or the workpieces are in danger of being damaged.
This can include:
- Physical damage to the Dispensing Valve or workpiece by unexpected Dispensing
Head movement.
- Thermal damage to the workpiece due to overheating of Heat Tooling.
- Electrical damage to the dispensing system.