Manual

Detailed Descriptions of ACL Commands 3-51
OR <x index>, <y index> Output Correction
This command causes the Automove System to output a pair of correction offsets as
previously established via the CR command. The X value is output, then a comma, then the
Y value. The values are in microsteps, in the range -128.0000 through 127.0000, except as
described below.
<x index> and <y index> determine which location within the XY Linearity Correction
Table is to be output; they correspond to the <x index> and <y index> parameters of the
CR command, and must be in the range 0 through 7, except for the special case described
below.
If <x index> and <y index> are both -1 (minus 1) then the OR command outputs the X and
Y grid spacing of the linearity correction grid, in microsteps. The numbers are in the range
0.0313 through 32767.0000.
For more information about the OR command please see Chapter 9 Linearity Correction.