Manual
Changing the Personality 7-11
43: Default Arrow Mode, range 0 to 255, factory 0
This parameter sets the default Arrow mode which is applied at power up, at IN, and at an
AM with no parameters. See the AM command in Chapter 3 and the Z AXIS button in
Chapter 4.
44: Default Z Axis Step Rate, range 1 to 10000, factory 100
This sets the default Z axis step rate which is applied at power up, at IN, and at a CZ with
the <rate> parameter omitted. See the CZ command in Chapter 3.
45: Default Z Axis Modulus, range 1 to 32767, factory 32767
This sets the default Z axis modulus which is applied at power up, at IN, and at a CZ
command with the <mod> parameter omitted.
46: Default Z Axis Half Step Mode, range 0 to 255, factory 1
This sets the default Z axis half-step flag which is applied at power up, at IN, and at a CZ
command with the <halfflag> parameter omitted.
47: Default Z Axis Acceleration, range 1 to 10000, factory 40
This sets the default Z axis acceleration which is applied at power up, at IN, and at a CZ
command with the <accel> parameter omitted.
48: Default Find-Z-Before-XY-Home, range 0 to 255, factory 0
This parameter controls whether the Z Home switch is always found automatically before
the X and Y switches in an FH command or XY manual re-reference operation. It also
controls whether the GO TO ORIGIN button's XY motion is preceded by an automatic Z
Find Home. (This can be used to prevent crashing into fixturing, etc., during the XY
motion.) See the FH and FZ commands in Chapter 3; see also the GO TO ORIGIN button
and the manual re-reference operation in Chapter 4.
Table 27 - Find-Z-Before-XY-Home Default Value Interpretations
Value FZ before FH FZ before GO TO ORIGIN
0 No No
1 Yes Yes
2 Yes No
3 No Yes
other Yes Yes