5.See Figure 4. Turn the pressure controller valve to the ON position
and set the fluid pressure as desired.
6.If using a co-axial air nozzle, set the desired air pressure. The
co-axial air pressure regulator and gauge are typically installed on the
workcell front panel.
7.Place a test sheet under the applicator nozzle and run a dispense
program. Check the results and adjust the dispense parameters as
desired.
Dispensing is controlled by the following parameters:
Needle Travel
The micrometer on top of the applicator adjusts
needle travel. Rotate the micrometer knob
counterclockwise to increase needle travel and
the amount of flux dispensed each time the valve
is opened.
Dispense Time Dispense time is set at the ACJ-1 controller.
Increase the dispense time to increase the
amount of time the valve is open and the amount
of flux dispensed.
Fluid Pressure Fluid pressure is with the pressure regulator on
the pressure controller.
Nozzle Size and
Type
Contact your Nordson representative for
information on available nozzles and
applications.
Z-Height Z-Height is set in your dispense program.
Contact your Nordson representative for advice
on setting the correct Z-height for your
application.
Co-Axial Air
Nozzles and
Pressures
The pattern width and orifice size of the nozzle
and the air pressure will affect the dispense
pattern. Contact your Nordson representative for
advice on the correct nozzle and pressure to use
for your application.