Optional Co-Axial Air Nozzles
Co-axial air nozzles are installed on the applicator directly on the fluid
nozzle. Air flowing from the nozzle helps the dispensed flux spread out
on the substrate, providing even coverage. Four sizes of air nozzles are
available:
narrow face, .030-in. orifice
medium face, .030-in. orifice
wide face, .030-in. orifice
medium face, .050-in. orifice
To use a co-axial air nozzle, you must install a co-axial air kit containing a
solenoid valve and cordset. Air is supplied to the solenoid valve from a
pressure regulator installed in the front panel of the workcell. Refer to the
Parts
section for nozzle and kit part numbers. Contact your Nordson
representative for information on ordering and installing a regulator and
plumbing.
Optional Heaters
The heater kits include a heater, cable, and electrical connector. The kit
connects to a separate temperature controller (power manager), installed
in the cabinet under the workcell coating area. Contact your Nordson
representative for information on the temperature controller.
NOTE: Heaters cannot be installed on the 10 cc ACJ-S applicator.
The RTD and heater cartridges can be replaced by ordering the kits listed
in the
Parts
section.
Optional Fluid Nozzles
Fluid nozzles are available in different sizes and configurations. Contact
your Nordson representative for information on fluid nozzles.