See Figure 4. The fluid pressure controller is typically mounted in the
workcell coating area. Maximum input air pressure is 7 bar (100 psi).
1246004A
FLUID PRESSURE
OFF
ON
1
2
3
4
Fig. 4 Pressure Controller
1. Digital pressure display
2. Pressure regulator
3. Air supply indicator
4. Valve
The following options are available:
Fluid systems for ACJ-ST applicators
Co-axial air nozzles
Heaters
Fluid nozzles
Optional Fluid Systems for ACJ-ST Applicators
Fluid systems consist of a reservoir, pressure relief valve, 140 micron
filter, and the hoses, tubing, and fittings required to install the systems on
a Century workcell. The fluid system kits are available with three sizes of
reservoirs:
17.75 centiliters (6 fluid ounces)
59.1 centiliters (20 fluid ounces)
3.75 liters (1 gallon)