Owner manual

ACJ Series Applicator Systems
8
2000 Nordson Corporation
All rights reserved
303 810A
Issued 1/00
Manual 12-46
ACJ-ST Applicators
ACJ-ST applicators are supplied with flux from an external, pressurized
reservoir. ACJ-ST applicators are available in the following versions:
without heater
with heater
See Figure 3. The controller is typically mounted in the cabinet under the
workcell coating area. It operates on 120 Vac and outputs 24 Vdc to
energize the applicator solenoid for a selected time period.
1246003A
I
O
X1
X
1
/
10
X
1
/
100
TRG
TIMER
OUTPUT
MAN
TRG
TIME (msec)
Nordson
ACJ-1 Controller
FUSE
POWER
123
5
4
678
Fig. 3 ACJ-1 Controller
Item Description Function
1 Power switch Turns on the timer, switch lights when power is on.
2 Fuse Midget 1 amp main fuse.
3 Manual trigger button Energizes the applicator solenoid for the set time.
4 Trigger indicator lamp Lights when the timer receives a trigger signal.
5 Timer indicator lamp Lights while the timer is operating.
6 Output indicator lamp Lights when the timer energizes the applicator solenoid.
7 Range mode select switch x1: 0–9999 milliseconds
x1/10: 0–999.9 milliseconds
x1/100: 0–99.99 milliseconds
8 Timer setting Sets the dispense time in milliseconds. 5 milliseconds
minimum.
ACJ-1 Controller