ACJ-Series Applicator Systems Customer Product Manual Part 303 810A NORDSON CORPORATION AMHERST, OHIO USA
Nordson Corporation welcomes requests for information, comments and inquiries about its products. General information about Nordson can be found on the Internet using the following address: http://www.nordson.com. Address all correspondence to: Nordson Corporation Attn: Customer Service 555 Jackson Street Amherst, OH 44001 Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date 2000.
Table of Contents i Table of Contents 1. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Qualified Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Regulations and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Personal Safety . . . . . . . . . . . . . . . . . . . .
ii Table of Contents 5. Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Using the Illustrated Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Applicator Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Applicator Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 10cc ACJ-S Applicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACJ Series Applicator Systems 1 ACJ Series Applicator Systems 1. Safety Read and follow these safety instructions. Task- and equipment-specific warnings, cautions, and instructions are included in equipment documentation where appropriate. Make sure all equipment documentation, including these instructions, is accessible to persons operating or servicing equipment.
2 ACJ Series Applicator Systems Personal Safety To prevent injury follow these instructions. Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices. Keep clear of moving equipment. Before adjusting or servicing moving equipment, shut off the power supply and wait until the equipment comes to a complete stop.
ACJ Series Applicator Systems 3 High-Pressure Fluids High-pressure fluids, unless they are safely contained, are extremely hazardous. Always relieve fluid pressure before adjusting or servicing high pressure equipment. A jet of high-pressure fluid can cut like a knife and cause serious bodily injury, amputation, or death. Fluids penetrating the skin can also cause toxic poisoning. If you suffer a fluid injection injury, seek medical care immediately.
4 ACJ Series Applicator Systems Fire Safety To avoid a fire or explosion, follow these instructions. Ground all conductive equipment in the spray area. Use only grounded air and fluid hoses. Check equipment and workpiece grounding devices regularly. Resistance to ground must not exceed one megohm. Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected.
ACJ Series Applicator Systems 5 Halogenated Hydrocarbon Solvent Hazards Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components. Under pressure, these solvents can react with aluminum and explode, causing injury, death, or property damage.
6 ACJ Series Applicator Systems 2. Description The ACJ Series applicator systems are typically used in Nordson Century workcells to dispense solder flux on printed circuit boards and other electronic components. This section describes the system components and their functions, and the different applicator versions and options. System Components and Functions Figure 1 shows a typical ACJ system with options.
ACJ Series Applicator Systems Applicators 7 See Figure 2. Two applicator versions are available. 1 2 3 4 4 5 6 7 ACJ-S ACJ-ST 1246002A Fig. 2 ACJ-S and ACJ-ST Applicators 1. 2. 3. 4. Micrometer Solenoid Body Air inlet fitting 5. Bracket 6. Syringe 7. Fluid inlet fitting ACJ-S Applicators ACJ-S applicators have an integral reservoir (syringe) that holds the flux supply. The syringe is completely sealed and pressurized to ensure a steady flow of material.
8 ACJ Series Applicator Systems ACJ-ST Applicators ACJ-ST applicators are supplied with flux from an external, pressurized reservoir. ACJ-ST applicators are available in the following versions: without heater with heater See Figure 3. The controller is typically mounted in the cabinet under the workcell coating area. It operates on 120 Vac and outputs 24 Vdc to energize the applicator solenoid for a selected time period.
9 ACJ Series Applicator Systems Fluid Pressure Controller See Figure 4. The fluid pressure controller is typically mounted in the workcell coating area. Maximum input air pressure is 7 bar (100 psi). 1 FLUID PRESSURE 3 2 OFF ON 4 1246004A Fig. 4 Pressure Controller 1. Digital pressure display 2. Pressure regulator Options 3. Air supply indicator 4.
10 ACJ Series Applicator Systems Optional Co-Axial Air Nozzles Co-axial air nozzles are installed on the applicator directly on the fluid nozzle. Air flowing from the nozzle helps the dispensed flux spread out on the substrate, providing even coverage. Four sizes of air nozzles are available: narrow face, .030-in. orifice medium face, .030-in. orifice wide face, .030-in. orifice medium face, .050-in.
ACJ Series Applicator Systems 11 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. 3. Operation Refer to your Century workcell manual for system setup and operating procedures. Startup 1. See Figure 4. Turn the pressure controller valve to the OFF position. 2. Fill the ACJ-S syringe or ACJ-ST reservoir: ACJ-S Applicators: a. Remove the thumbscrew from the applicator bracket. b.
12 ACJ Series Applicator Systems Startup (contd) 5. See Figure 4. Turn the pressure controller valve to the ON position and set the fluid pressure as desired. 6. If using a co-axial air nozzle, set the desired air pressure. The co-axial air pressure regulator and gauge are typically installed on the workcell front panel. 7. Place a test sheet under the applicator nozzle and run a dispense program. Check the results and adjust the dispense parameters as desired.
ACJ Series Applicator Systems Short-Term Shutdown 13 1. Shut off the ACJ-1 power switch. 2. Turn the pressure controller valve to the OFF position. Long-Term Shutdown If the flux will deteriorate during a long-term shutdown perform the following procedures: 1. If you are using an ACJ-ST applicator, empty the reservoir and fill it with a compatible solvent. Run a purge program and flush the system. 2. Shut off the ACJ-1 controller power switch. 3. Turn the pressure controller valve to the OFF position.
14 ACJ Series Applicator Systems WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. 4. Troubleshooting This section contains troubleshooting procedures that cover the most common problems you may encounter. If you cannot solve the problems with the information given here, contact your local Nordson representative for help. Troubleshooting Chart Problem 1. 2. 3.
ACJ Series Applicator Systems Problem 4. 5. Flux leaking from nozzle, no cut-off Flux leaking between seat and syringe (ACJ-S) or seat adapter (ACJ-ST). 2000 Nordson Corporation All rights reserved Possible Cause Corrective Action Nozzle not installed properly Remove nozzle and reinstall. Damaged nozzle gasket Replace gasket Hardened material preventing needle from seating properly Remove seat, clean seat and needle. Needle or seat damaged Replace needle and seat.
16 ACJ Series Applicator Systems 5. Parts To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use this five-column parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts List Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list. The code NS (not shown) indicates that a listed part is not illustrated.
17 ACJ Series Applicator Systems Applicator Part Numbers Part Description 329362 Applicator, ACJ-S, 10 cc 329 363 Applicator, ACJ-S, 30 cc 329 365 Applicator, ACJ-S, 30 cc, with heater 329361 Applicator, ACJ-ST 329 413 Applicator, ACJ-ST with heater Applicator Repair Kits Refer to the applicator parts lists for kit contents.
18 ACJ Series Applicator Systems See Figure 5. 10cc ACJ-S Applicator Item Part Description Quantity — 329 362 Applicator, ACJ-S, 10 cc 1 1 995 215 Adjuster, micro, ACJ 1 2 995 326 Nut, housing, ACJ 1 3 329 374 Solenoid, ACJ applicator 1 4 995 325 Cap, housing, ACJ 1 5 995 592 Plug, O-ring, ACJ 1 6 995 597 O-ring, ACJ, 3 mm 1 7 995 591 Sleeve, micro-adjust, ACJ 1 8 940 190 O-ring, 0.8125 x 0.9375 x 0.063 in.
ACJ Series Applicator Systems 19 1 2 3 4 5 6 7 8 9 10 11 17 18 12 8 13 14 15 19 20 16 21 1246005A Fig.
20 ACJ Series Applicator Systems See Figure 6. This parts list includes both the 30cc ACJ-S applicator without heater and the 30cc ACJ-S applicator with heater.
ACJ Series Applicator Systems 21 1 2 3 4 5 6 7 8 9 10 11 12 17 8 13 14 15 18 16 23 19 22 20 24 21 1246006A Fig.
22 ACJ Series Applicator Systems See Figure 7. This parts list covers both the ACJ-ST applicator without heater and the ACJ-ST applicator with heater.
ACJ Series Applicator Systems 23 1 2 3 4 5 6 7 8 9 15 10 6 14 11 13 8 16 17 12 18 19 20 21 22 23 24 29 30 25 22 26 18 31 15 28 27 1246007A Fig.
24 ACJ Series Applicator Systems System Accessories System accessories are required for applicator operation. They include the pressure controller, ACJ-1 controller, and cables. The power manager that controls the optional heaters is a component of the Century workcell. Pressure Controller See Figure 8.
ACJ Series Applicator Systems 25 1 2 FLUID PRESSURE 3 OFF ON Front View 4 1 5 6 2 7 3 Main Air (Front Panel) 4 10 6 To Reservoir Main Air 8 9 Side View 1246008A Fig.
26 ACJ Series Applicator Systems ACJ-1 Controller and Mounting Brackets Part Description Note 329 393 Kit, controller, ACJ-1, 115V timer 326 388 Bracket, Century, rack mount A 326 391 Bracket, rack mount, Century A NOTE A: Not included with controller. Order separately. System Cables See Figure 9.
27 ACJ Series Applicator Systems Options include fluid systems, co-axial air nozzles, and heater kits. Options Six- and Twenty-Ounce Fluid System Kits See Figure 10. Item Part Description Quantity Note — ------ Kit, 6 oz fluid system 1 — ------ Kit, 20 oz fluid system 1 1 971 248 Connector, 0.25 in. tube x 0.125 NPT 1 2 310 717 Tubing, PFA Teflon, 0.25 in. OD x 0.062 in. wall AR A 3 900 620 Tubing, spiral cut, 0.375 in.
28 ACJ Series Applicator Systems 1 2 3 4 5 6 View A–A 7 To Applicator 8 9 10 20 A 19 21 A 17 17 18 11 16 From Pressure Controller 15 12 14 13 1246010A Fig.
29 ACJ Series Applicator Systems Co-Axial Air Kit See Figure 11. Item Part Description Quantity — 322 360 Kit, co-axial air 1 310 777 Tubing, polyurethane, 0.125 x 0.
30 ACJ Series Applicator Systems Co-Axial Air Nozzles These nozzle must be ordered separately. They are not included in the co-axial air kit. Part Description 329 410 Co-axial air nozzle, N3 (narrow face, 0.030-in. orifice) 329 391 Co-axial air nozzle, M3 (medium face, 0.030-in. orifice) 329 411 Co-axial air nozzle, W3 (wide face, 0.030-in. orifice) 322 445 Co-axial air nozzle, M5 (medium face, 0.050-in. orifice) Note Heater Kit See Figure 12.