Check that main door catch closes correctly. Adjustment
can be achieved by tightening or loosening the bolts
securing the Smoke Control bracket.
Refit the heat shield, ensuring that the all 4 fixing slots
locate on the screws.
Tighten the 4 screws.
Uno 2 only
Locate the bottom holes of the lower panel onto the studs
at the base of the appliance.
Push the top of the panel towards the appliance until
secured by the catches.
Uno 4 only
Replace the internal cover ensuring that the left hand
cutouts locate around the hinges and the hole on the right
hand side locates over the door catch.
Close the door under the combustion chamber.
Uno 2 & 4
Close the main door.
All Models
The new Smoke Control stop will now restrict the
movement of the air control in order to comply with
Smoke Control Regulations.
An appliance modified for Smoke Control can be
recognised in the following manner:
The air vent control has restricted movement and will not
close past the 25mm open position.
25mm
For appliances that have not been fitted with the Smoke
Control kit the air vent control can be shut down
completely.
Fully Closed
The Air Control on appliances modified for Smoke Control
cannot shut down completely.