1. General
These instructions apply to the Uno products when fitted
with a Smoke Control kit.
NOTE: This appliance has been independently tested to
PD6434 and has been exempt from the controls that
generally apply in smoke control areas hence are
considered suitable for use in Smoke Control Area when
burning wood and ONLY when fitted with the relevant
Smoke Control kit detailed below.
Appliance Smoke control kit Part No.
Uno 1 NP-UNOSZKIT
Uno 2 NP-UNOSZKIT
Uno 4 NP-UNOSZKIT
To meet the Smoke Control requirement this appliance
must be operated correctly in order to minimise the
amount of smoke produced.
Burn dry wood only.
These instructions must be left with the user and kept
with the original instructions which they now supersede.
2. Recommended Fuels
Wood Logs:
Burn only seasoned timber with a moisture content of
less than 20%. To ensure this, allow cut wood to dry for
12 to 18 months.
Poor quality timber:
• Causes low combustion efficiency.
• Produces harmful condensation.
• Reduces effectiveness of the air control and life of
the appliance.
Do not burn construction timber, painted, impregnated /
treated wood, manufactured board products or pallet
wood.
3. Lighting
You can check whether the flue has enough draught by
lighting a ball of paper above the baffle plate. A cold flue
often does not have enough draught and consequently,
some smoke may escape into the room instead of up the
chimney. By lighting the fire in the way described here,
you can avoid this problem.
Stack two layers of logs crosswise.
Recommended Log Size
Length (max) 30cm x 10cm diameter (max)
Quantity 0.78kg (2 logs)
Stack two layers of kindling crosswise on top of the logs.
Place a firelighter cube in the lower layer of kindling and
light the cube according to the instructions on the
packaging.
Close the door of the appliance and open the air vent
control fully; see the diagram over page. Additional
ignition air can be obtained by leaving the door open
slightly. When the flames are stable and the chimney
warm close the door, or overheating can occur, which is
not covered by the warranty.
The air supply can then be regulated with the air vent
control.
Let this fire develop into a good blaze until there is
glowing bed of charcoal. You can then add fuel and
adjust the air vent control, see the notes on refuelling the
appliance.