Uno 1, 2, 4 Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas These instructions for fitting and operating the Smoke Control kit must be read in conjunction with the following product Installation Instructions. Uno: PM1082 Issue 1 (14.05.
1. General 3. Lighting These instructions apply to the Uno products when fitted with a Smoke Control kit. You can check whether the flue has enough draught by lighting a ball of paper above the baffle plate. A cold flue often does not have enough draught and consequently, some smoke may escape into the room instead of up the chimney. By lighting the fire in the way described here, you can avoid this problem.
Open stacking Air Controls A = Ignition Air Control Air Vent Control Open stacking allows oxygen to easily reach every part of the fire. Compact stacking Ignition air vent control The Uno has an integral air vent combined with the main combustion air control. This is activated by pushing the control fully back to the maximum open position. This is used to provide additional combustion air when first lighting the appliance and refuelling.
If the fire subsides when the air vent control is closed, re-open the air vent control to re-establish the flames. Experience establishes settings to suit personal preferences. Do not burn large amounts of fuel with the air vent control closed for long periods of time. This reduces the glass cleaning effect and causes tars and creosotes to build-up in the appliance and flue system and will produce excessive amounts of smoke.
These instructions cover the fitting of the Smoke Control Kit Fit the Smoke Control bracket and secure with the washers and bolts previously removed. 1. Parts List Appliance Smoke control kit Part No. Uno 2 NP-UNOSZKIT Uno 1 Uno 4 NP-UNOSZKIT Smoke Control Bracket NP-UNOSZKIT Kit contents: 1 x Smoke Control Bracket 2. Smoke Control Kit - Fitting Instructions Tools required: 8mm Spanner Crosshead Screwdriver.
Uno 4 only Pull open the hinged door under the combustion chamber. Carefully pull the heat shield forward to disengage the slots from the screws and remove. To remove the internal cover: Pull the right hand side forward to disengage from the door catch. Move the left hand side inwards to disengage the cutouts from the door hinges. Slide the internal cover forward to remove. Remove the 2 bolts and washers from the right hand side. Open the main door.
Check that main door catch closes correctly. Adjustment can be achieved by tightening or loosening the bolts securing the Smoke Control bracket. Refit the heat shield, ensuring that the all 4 fixing slots locate on the screws. Tighten the 4 screws. Uno 2 only Locate the bottom holes of the lower panel onto the studs at the base of the appliance. Push the top of the panel towards the appliance until secured by the catches.
The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area.