Instruction Manual
9
GB
Lateral outlet
FIG 2A: Unscrew sealing lid on the lateral outlet
FIG 2B: Bend out the fastening bracket belonging to
the sealing lid
FIG 2C: Fasten the ue outlet collar on to the lateral
outlet
FIG 2D: Fasten the sealing lid on the rear outlet. We
recommend to use stove cement to ensure that it is
completely sealed o.
Top outlet
FIG 3A: Unscrew sealing lid on the top
FIG 3B: Fasten the ue outlet collar
FIG 3C: Fasten the sealing lid on the rear outlet. We
recommend to use stove cement to ensure that it is
completely sealed o.
Rear outlet
FIG 4: Fasten the ue outlet collar
Connection of the Flue
Please be aware when connecting the 125 mm ue
to the smoke dome that the ue is placed inside
the ue outlet collar. Use stove cement in the joints.
For the ue connection to the chimney, follow the
recommendations from the chimney manufacturer.
Operating Control
When the stove is in position, check that all functions
are easy to manoeuvre and appear satisfactory
Behind one of the front legs there is a hook for the
cool handle. (FIG 7)
Air vent control (FIG 5)
Left
Right
Open
Closed
Door (FIG 6)
Handle to the right
Handle to the left
Open
Closed
5. Lighting the Fire for the First Time
When the stove is assembled and all instructions
have been observed, a re can be lit. Be careful with
touching the stove the rst few times it is used as it
may damage the varnish.
Take care when inserting logs into the burn chamber,
in order not to damage the Thermotte plates. Please
note that during the rst few rings, the insulations
panels within the rebox will release moisture
contained within them from production. This will slow
down the burn rate slightly and could cause markings
on the glass. These are easily removed with glass
cleaner once the glass has gone cold. Possibly leave
the door slightly open the rst 2-3 times that the
stove is used. It is advisable to ventilate the room
2. Technical Information
The stoves from Nordpeis have secondary
combustion and are clean burning. The combustion
takes place in two phases: rst the wood burns and
then the gases from the fumes are lit by the hot air.
This ensures that these new stoves have minimal
emissions of soot particles and unburnt gases (such
as CO) and are thus better for the environment. Clean
burning stoves require a small amount of wood in
order to obtain a good heat output. Use exclusively
clean and dry wood. We recommend seasoned
hardwood with a maximum moisture content of 20%.
Product Orion
Material: Cast iron
Weight Stove 72 kg
Surface treatment door/
doorframe:
Heat resistant varnish
Fuel: Wood logs, 30 cm
Operating range: 1-6 kW
Nominal heat output kW] 3
Eciency [%] 84,2
CO @13% O2 0,12
Flue gas temperature [°C)] 181
Draught system: Air vent control
Combustion system:
Secondary
combustion (clean
burning)
Flue outlet: Top, lateral and rear
Flue: Outer Ø 125 mm
Possible to connect steel
chimney:
Yes
3. Distance to Combustible Material
Ensure that the safety distances are respected
(FIG 1).
The distance from the front of the stove to furniture
needs to be of at least 1 metre. When connecting
a steel chimney to the top outlet use the security
distances required from the manufacturer.
4. Assembly
The following tools are necessary:
• 4 mm Allen key
• 10 mm Wrench
• 13 mm Wrench
Orion is delivered with separate ue outlet collar.
Follow the correct instructions below depending on
which outlet is used (top, lateral or rear):