Datasheet
Revision 1.5 Page 12 of 41
nRF905 Product Specification
Table 8. Receiver operation
C/I
+5M
Blocking at +5MHz
a
-70 dB
C/I
-5M
Blocking at -5MHz
a
-65 dB
C/I
+10M
Blocking at +10MHz
a
-69 dB
C/I
-10M
Blocking at -10MHz
a
-67 dB
C/I
IM
Image rejection
a
-36 dB
a. Channel Level +3dB over sensitivity, interfering signal a standard CW, image lies 2MHz above
wanted.
Symbol Parameter (condition) Notes Min. Typ. Max. Units