Datasheet

Page 92 of 161
nRF8001 Product Specification
Revision 1.2
Table 31. System command/System event operating mode dependency
The following table lists the data commands and events available and their operating mode dependency:
Table 32. Data command/Data event operating mode dependency
CloseRemotePipe
Section 24.26 on page 131 0x1F
X
5
System events
DeviceStartedEvent
Section 26.1 on page 139 0x81 X X X
EchoEvent Section 26.2 on page 140 0x82
HardwareErrorEvent Section 26.3 on page 141 0x83 X
CommandResponseEvent Section 26.4 on page 142 0x84 X X
ConnectedEvent Section 26.5 on page 143 0x85 X
DisconnectedEvent Section 26.6 on page 145 0x86 X
BondStatusEvent Section 26.7 on page 146 0x87 X
PipeStatusEvent Section 26.8 on page 148 0x88 X
TimingEvent Section 26.9 on page 151 0x89 X
DisplayKeyEvent Section 26.10 on page 152 0x8E
X
4.
KeyRequestEvent Section 26.11 on page 153 0x8F
X
4.
1. Only available after a ConnectedEvent
2. Only available after a ConnectedEvent and the applicable pipe is listed in the PipesClosed bitmap
returned in the PipeStatusEvent
3. Valid only as a response to a KeyRequestEvent.
4. Is only generated after a
ConnectedEvent while in bonding mode.
5. Only available after the
OpenRemotePipe command has been successfully completed.
Packet Link to relevant section OP code
Operating mode
Setup Standby Active Sleep Test
Data commands
SetLocalData
Section 25.1 on page 133 0x0D X X
SendData Section 25.2 on page 135 0x15
X
1
1. Only available after a ConnectedEvent and the applicable pipe is listed in the PipesOpen bitmap
returned in the PipeStatusEvent
SendDataAck Section 25.3 on page 136 0x16
X
2
2. Only available after a ConnectedEvent and as a response to a DataReceivedEvent
RequestData Section 25.4 on page 137 0x17
X
2
SendDataNack Section 25.5 on page 138 0x18
X
2.
Data events
DataCreditEvent
Section 27.1 on page 154 0x8A X
DataAckEvent Section 27.4 on page 157 0x8B X
DataReceivedEvent Section 27.3 on page 156 0x8C X
PipeErrorEvent Section 27.2 on page 155 0x8D X X
Packet Link to relevant section OP code
Operating mode
Setup
Stand
by