Datasheet
Page 36 of 161
nRF8001 Product Specification
Revision 1.2
12.4 Current consumption parameters
The nRF8001 static current consumption is defined in Table 14. and Table 15. The dynamic current
consumption is defined in Figure 15. on page 37
.
The operating conditions are: VDD = 3.0V, T
A
= 40ºC to +85ºC. The numbers in the column called
Reference to figures 17 and 19 in Table 14. and Table 15. refer to the numbers found in Figure 17. on
page 39 and Figure 19. on page 41.
Table 14. Current consumption for static values when DC/DC not active
Symbol Parameter (condition)
Test
level
Reference
to figures
17 and 19
Min Nom Max Unit
I
RX
Peak current, receiver active IV 2 14.6 mA
I
TX,0dBm
Peak current, transmitter active,
P
OUT
= 0 dBm
IV 4 12.7 mA
I
TX,-6dBm
Peak current, transmitter active,
P
OUT
= -6 dBm
I 4 10.4 mA
I
TX,-12dBm
Peak current, transmitter active,
P
OUT
= -12 dBm
I4 8.9 mA
I
TX,-18dBm
Peak current, transmitter active,
P
OUT
= -18 dBm
I4 8.4 mA
I
TFS
Peak current when switching between
receive and transmit
I3 7 mA
I
MCU_HOST
Peak current for host processing I 6 5 mA
I
MCU_LL
Peak current for LL processing I 1 and 5 3.5 mA
I
Standby
Standby current, I 1 1.6 mA
I
idle
Current drain between connection/
advertising events
ACI = active mode, 32 kHz Osc active
I2µA
I
sleep
Current drain, connection-less state
ACI = sleep mode
I0.5µA