Datasheet
Page 110 of 161
nRF8001 Product Specification
Revision 1.2
24.13 RadioReset (0x0E)
RadioReset resets the radio transceiver and forcibly terminates any active connection or advertisement.
24.13.1 Functional description
This command resets the radio transceiver and returns nRF8001 to Standby mode. All dynamic data is
retained in memory after execution of the
RadioReset command. Executing RadioReset while in a
connection forcibly terminates the connection and returns nRF8001 to Standby mode without generating a
DisconnectedEvent.
See the operating mode during which this command can be used in Table 31. on page 92
. The command
will return a command response event with status ACI_STATUS_ERROR_DEVICE_STATE_INVALID
when it is used in the incorrect mode.
24.13.2 Message format
Table 49. ACI message structure for RadioReset
24.13.3 Accepted values
None
24.13.4 Returned events
This command returns a CommandResponsEvent.
Data returned in the
CommandResponseEvent is:
• Command code:
RadioReset
• Status: Success / Status code
• Response data: None
24.13.5 Bluetooth low energy procedures used
None
Message field/parameter
Value size
(bytes)
Data value Description
Header
Length 1 5 Packet length
Command 1 0x0E
RadioReset