1.
Feature
Input
Universal 100 ~ 240 Vac / 47 ~ 63 Hz Input, without any slide switch.
Output
+24V / 0 ~ 5A
Case Dimension
168.1(L) * 65.9(W) * 39(H) mm
Efficiency
Eff (av) 87%
Safety
CUL / UL / GS / PSE / BSMI / RCM
EMI
CE / FCC Class B Conduction & Radiation Met.
Protection
OVP (Over Voltage Protection)SCP (Short Circuit Protection)
OCP (Over Current Protection)OTP (Over Temperature Protection)
High frequency designless power consumption.
Suitable for usage at Telecommunication, Computer, Industrial Controller, & OA System.
Meet Energy Star V / Erp ( Stage 2 ) / MEPS V .
2.
Input
2.1 Voltage Universal 100 ~ 230Vac, single phase
2.2 Frequency 47 ~ 63 Hz
2.3 Current 1.6A Max.
2.4 Inrush Current
80A Max. / 230Vac (Cold start at 25 ºCfull load)
2.5 Efficiency
Eff (av) 87% (At 115 Vac & 230 Vac)
2.6 Power Consumption
Pi 0. 5 W ( At 230Vac & No load)
2.7 Power Factor (PF)
Pi 0. 9 ( At Full load)
E1 + E2 + E3 + E4
E1=efficiency with 25% rated load ; E2= efficiency with 50% rated load
※Eff (av) =
4
E3=efficiency with 75% rated load ; E4= efficiency with 100% rated load
3.
Output
3.1 DC Output Voltage
+24.00V ± 5%
Current 5A Max.
Regulation 22.8Vmin. ~ 24.0Vtyp. ~ 25.2Vmax.
Ripple & Noise 120mV Max.
Total Power 120W Max.
Remark : For ripple & noise measurement, use a 20MHz bandwidth frequency oscilloscope, and add a 0.1μF multilayer Cap. and a