Datasheet
DC-DC CONVERTERS
www.manson.com.hk P.28
SSDC-Series
◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa.
◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
Specifications
13.8VDC Switching Mode Step Down Converters (Isolated)
Features
Description
Input Voltage Range
Output Voltage
Continuous Output Current
Ripple & Noise (peak-peak)
Maximum Output Current
Load Regulation (0-100% load)
Line Regulation (20-30V variation)
Efficiency
Protection Devices
Cooling System
Indicators
Output Connection Type
Input Connection Type
CE Approvals
e-Mark Approvals
Input Fuse Type
Dimensions (WxHxD)
Weight
Accessory
Models
SSDC - 210 SSDC - 240
8A 35A
10A 40A
350mV 250mV
30mV 50mV
22 - 30VDC
13.8VDC
<100mVp-p
>86% >84%
Overload, Short Circuit
Natural Convection Variable Speed Thermally Control Fan
Power on LED
Cable Terminal
Cable Cable
EN 55011
e11 02 1520
Standard Car Blade Fuse
125x47x120 mm 4.9x1.9x4.7 inch 156x57x240 mm 6.1x2.2x9.5 inch
0.65 kg 1.4 lbs 2.2 kg 5 lbs
Nil Mounting Bracket
NIL
EN 55022
<250mVp-p
This Isolated Ground series provide negative / positive
ground reference compatibility, allowing connection
of negative ground equipment to positive or floating
ground battery system or vice versa. They offer
protection level for themselves and to the connected
loads. They also offer protection against transient
voltages spikes typically encountered on electric fork
lifts. Being switch mode, they have high efficiency
(>80%), produces little heat and are of small size for
the power they deliver.
•
•
•
•
•
•
•
•
•
Negative or positive ground reference
High efficiency 88%
Low profile , high power density
Protection against transient voltages
EMC INTERFERENCE IMMUNITY
22 - 30VDC input voltage
Overload and short circuit protection
Over current protection
LED power on indicator