Datasheet
B 4 / 9 20180907 Rev.:A0
3. GENERAL SPECIFICATIONS
◎
Efficiency
:
Full Load @ 115Vac ---------------------------- > 85%
Full Load @ 230Vac ---------------------------- > 85%
Minimum Average Efficiency in Active Mode ------------------- ≥ 89%
Maximum Power in No Load mode (W) -------------------------- ≤ 0.15
DoE Level VI , ErP CoC V.5, Tier II ---------------------------- Meet
Power Factor Correction @ 115Vac Full Load ------------------- > 0.9
◎
Turn-on Time
:
Full Load @115Vac ---------------------------- < 3Sec
◎
Hold-up Time
:
Full Load @115 Vac ---------------------------- > 16mSec
◎
Safety Ground Leakage Current
:
Class II type@230Vac 50Hz ----------------------------- < 0.25mA
◎
Withstand(Isolation) Voltage
:(
UL60950-1
;
EN60950-1 2nd
)
4242Vdc, 1 Minute from Input(L1&L2) to Output -------- < 10mA
2952Vdc, 1 Minute from Input(L1&L2) to Earth -------- < N/A
◎
Insulation Resistance
:
Input(L1&L2) to Output @ DC 500V ---------------------- > 100MΩ
Input(L1&L2) to Earth @ DC 500V ---------------------- > N/A
◎
MTBF
:
Full Load, MIL-HDBK-217F@25℃ ---------------------- > 100kHours
◎
Weight
:
Not Include Packing ----------------------------- < 480g
4. PROTECTION SPECIFICATIONS
◎
Brown-Out Protection
:
(Input Voltage drops down to zero then back to nominal slowly)
All Outputs ----------------------------- Hiccup / Auto-recovery
◎
Overvoltage Protection
:(
Latch
)
V1 Overvoltage Range ----------------------------- 110%~200%
◎
Overcurrent(Overload) Protection
:(
Overcurrent Range @110%~200% above Rating Load
)
All Outputs ----------------------------- Hiccup / Auto-recovery
◎
Short Circuit Protection
:
All Outputs ----------------------------- Hiccup / Auto-recovery