Datasheet

B 3 / 9 20180907 Rev.:A0
1. INPUT SPECIFICATIONS
Input Range
Parameter Conditions / Description Min. Nom. Max.
Units
Voltage
Universal-AC Input normal voltage 100 115/230
240 Vac
Universal-AC Input ranging voltage 90 115/230
264 Vac
Current
@115Vac 90W Load -- -- 2 Arms
@230Vac 90W Load -- -- 1 Arms
Frequency
Auto-ranging 47 50/60 63 Hz
Inrush Surge Current
Cold Start @115Vac, at 25 ------------------------- 60A
Cold Start @230Vac, at 25 ------------------------- 100A
2. OUTPUT SPECIFICATIONS
Output Power
Convection Rating ------------------------- 90W Max.
Output Range
Voltage (Vdc)
Load Range (A)
Line
Regulation
(%)
Load
Regulation
(%)
(Note 1)
Ripple&Noise
(PARD)
(mVp-p)
(Note 2)
MIN.
Max.
(Convection)
S2
+12V 0A 7.5A ±0.5%
11.4~12.6Vdc
(±5%)
240mVp-p
Note : 1.Load regulation is tested at 10% to 100% of rated load.
2.Peak-to-peak for 90W (convection rating) @115Vac MIN. ; Measurements with a 20MHz bandwidth
and terminated with a 22uF electrolytic Cap. in parallel with a 0.1uF ceramic Cap.
Overshoot/Undershoot
Turn-on / turn-off ---------------------------- <10%