1.
Feature
Input
Universal 100 ~ 240 Vac / 47 ~ 63 Hz Input, without any slide switch.
Output
+12V / 0 ~ 12.5A
Case Dimension
175.2 (L) * 74 (W) * 42 (H) mm
Efficiency
Eff (av) 87%
Safety
CUL / UL / GS / PSE / BSMI
EMI
CE / FCC Class B; Conduction & Radiation Met.
Protection
OVP (Over Voltage Protection), SCP (Short Circuit Protection),
OCP (Over Current Protection), OTP (Over Temperature Protection)
High frequency design, less power consumption.
Suitable for usage at Telecommunication, Computer, Industrial Controller, & OA System.
Meet Energy Star V / Erp ( Stage 2) / MEPS V .
2.
Input
2.1 Voltage Universal 100 ~ 240Vac, single phase
2.2 Frequency 47 ~ 63 Hz
2.3 Current 2.2 A Max.
2.4 Inrush Current 100 A Max. / 230Vac (Cold start at 25 ºC, full load)
2.5 Efficiency
Eff (av) 87% (At 115 Vac & 230 Vac)
2.6 Power Consumption
Pi 0.5 W ( At 230Vac & No load)
2.7 Power Factor (PF)
Pi 0.9 ( At Full load)
E1 + E2 + E3 + E4
E
1
=efficiency with 25% rated load ; E
2
= efficiency with 50% rated load
※Eff (av) =
4
E
3
=efficiency with 75% rated load ; E
4
= efficiency with 100% rated load
3.
Output
3.1 DC Output Voltage
+12.00 V ± 5%
Current 12.5 A Max.
Regulation 11.4 Vmin. ~ 12.0 Vtyp. ~ 12.6 Vmax.
Ripple & Noise 240 mV Max.
Total Power 150W Max.
Remark: For ripple & noise measurement, use a 20MHz bandwidth frequency oscilloscope, and add a 0.1μF multilayer Cap. and a
Low ESR Electrolytic Cap. (10 μF) at output connector terminals. (At nominal line voltage, full load)