Datasheet
AM9825A-L SWITCHING ADAPTOR SPECIFICATIONS 
Ver: 0            Date: 2011/2/22                             
AMPLUS
                                  AM10267L.doc              Page 
7
1
RD
1
SPECIFICATION
  F. LOW TEMPERATURE STORAGE TEST 
Keep on    -30 (Packing) for 168 hours, and check the action after 3 hours in 25. 
RESULT: All normal function and meet specification. 
        G. HIGH TEMPERATURE STORAGE TEST 
Keep on    +70 (Packing) for 168 hours, and check the action after 3 hours in 25. 
RESULT: All normal function and meet specification. 
        H. HIGH HUMIDITY STORAGE TEST   
Keep on +4595%RH (Packing) for 168 hours, and check the action after 3hour in 25. 
RESULT: All normal function and meet specification. 
        I. TEMPERATURE CYCLE TEST   
Keep on -45(Packing) for 1 hour, then keep on +85(Packing) for 1 hour 
Repeat this cycle until 10 cycle, check the action after an hour in 25. 
RESULT: All normal function and meet specification. 
J. CURRENT- CARRYING OF HIGH VOLTAGE TEST 
Select power consumption at a standard load condition. The test samples shall be active with 
input voltage is 280V/50Hz,50,48 hours, confirm its operation after left in the standard 
condition for 1 hour. 
RESULT:any case deformation, smoking, or burn by heat should not be found. 