Datasheet
AM9825A-L SWITCHING ADAPTOR SPECIFICATIONS
Ver: 0 Date: 2011/2/22
AMPLUS
AM10267L.doc Page
7
1
RD
1
SPECIFICATION
F. LOW TEMPERATURE STORAGE TEST
Keep on -30 (Packing) for 168 hours, and check the action after 3 hours in 25.
RESULT: All normal function and meet specification.
G. HIGH TEMPERATURE STORAGE TEST
Keep on +70 (Packing) for 168 hours, and check the action after 3 hours in 25.
RESULT: All normal function and meet specification.
H. HIGH HUMIDITY STORAGE TEST
Keep on +4595%RH (Packing) for 168 hours, and check the action after 3hour in 25.
RESULT: All normal function and meet specification.
I. TEMPERATURE CYCLE TEST
Keep on -45(Packing) for 1 hour, then keep on +85(Packing) for 1 hour
Repeat this cycle until 10 cycle, check the action after an hour in 25.
RESULT: All normal function and meet specification.
J. CURRENT- CARRYING OF HIGH VOLTAGE TEST
Select power consumption at a standard load condition. The test samples shall be active with
input voltage is 280V/50Hz,50,48 hours, confirm its operation after left in the standard
condition for 1 hour.
RESULT:any case deformation, smoking, or burn by heat should not be found.