Datasheet
AM9825A-L SWITCHING ADAPTOR SPECIFICATIONS 
Ver: 0            Date: 2011/2/22                             
AMPLUS
                                  AM10267L.doc              Page 
6
1
RD
1
SPECIFICATION
B. DC OUTPUT CORD PUSH/PULL TEST OF ADAPTOR SIDE
Test condition: 8kgf X10sec at 5 direction verticality 
RESULT: No cutting inner wire is acceptable 
C. CORD BENDING TEST OF I/O CONECTOR SIDE
Test condition:    60’+60’=1 cycle,    30 cycle/1min, weight = 200g ,   
from step 1 to step 2 continuously   
      Step 1.    2000 cycle for difficult bending direction 
      Step 2.    3000 cycle for easy bending direction   
RESULT: No cutting inner wire is acceptable 
                                    STEP1                                              STEP2 
D. CORD BENDING TEST OF ADAPTOR SIDE 
Test condition:    60’+60’=1 cycle,    30 cycle/1min, weight = 500g ,   
from step 1 to step 2 continuously   
      Step 1.    500 cycle for difficult bending direction 
      Step 2.    500 cycle for easy bending direction   
RESULT: No cutting inner wire is acceptable 
        E. INDIVIDUAL DROP TEST     
Test condition:    6 face, each face 1 time 70 cm, on the 5mm wooden board.                                             
RESULT: Without opening of case and crack, etc. electric characteristic shall be 
satisfied.light crack after test is acceptable. 
8kgfx10s
5kgfx10s
5kgfx10s
5kgfx10s
5kgfx10s
60
60' 
60' 
60' 