Datasheet
AM 09257H SWITCHING ADAPTOR SPECIFICATIONS
Ver: 1 Date: 2011-05-28
AMPLUS
AM09257 Page
4
1
RD
1
SPECIFICATION
The S.M.P.S will shut down automatically when the AC input voltage lower than AC 90 V.
The S.M.P.S output voltage will drop to very low when overload by overload protection.
The S.M.P.S should not be fired or emitted smoke by protection when the circuit is short.
The S.M.P.S will shut down automatically when output voltage is over 28.5V by overvoltage
protection.
The S.M.P.S build-in thermal protector, when the transformer over heat (raise to 105),the circuit
will be shut down by PWM IC thermal protector.
The S.M.P.S can be changeable output voltage by changeable slot.
6.
DC INSULATION RESISTANCE
Input – Output : 50MΩminimum (at 500VDC)
Input – Body metal : 50MΩminimum (at 500VDC)
7.
DIELECTRIC WITHSTAND - VOLTAGE
Input – Output : 3750VAC minimum (2s)
Input – Body metal : 3750VAC minimum (2s)
8.
MAIN FUSE
Input fuse is 3.15A 250V
9.
INRUSH CURRENT
Peak inrush current shall be limited to 30A for a cold start
10.
TIME SEQUENCE
Time sequence should be satisfied to power ON/OFF, restart in
power failure
AC switch at ON/OFF
100%V
95%V
95%V
≧20m S ≦1 .0S
AC input
DC onput