Datasheet
AM 0055H (09262H) SWITCHING ADAPTOR SPECIFICATIONS
Ver: 1 Date: 2011-05-28
AMPLUS
AM09262 Page
5
1
RD
1
SPECIFICATION
12.
SAFETY STANDARD
To meet ETL-UL1950,CETL-C22.2 NO.950, GS-DIN EN60950
AS/NZS 4665.1 : 2005, EuP 2005/32/EC
13.
RFI EMISSION
EN55022: 2006+A1
EN61000-3-2: 2000
EN61000-3-3: 1995+A1
EN55024: 1998+A1+A2
FCC PART 15
14.
OUTPUT RATED & ELECTRICAL SPECIFICATIONS
RATED OUTPUT (V)
12 13 14 15 16 17 18 19 20 21 22 23 24
Rated current(A)
2.5 2.4 2.3 2.2 2.1 2.0 1.95 1.9 1.85 1.8 1.75 1.7 1.65
Max. output voltage(V)
12.5 13.5 14.5 15.5 16.5 17.5 18.5 19.5 20.5 21.5 22.5 23.5 24.5
Min. output voltage(V)
11.5 12.5 13.5 14.5 15.5 16.5 17.5 18.5 19.5 20.5 21.5 22.4 23.4
Ripple & Noise(mV)
<150 <150 <150 <150 <150 <150 <150 <150 <150 <150 <150 <150 <150
Over load current(A)
>4.0 >3.7 >3.5 >3.4 >3.2 >3.1 >3.0 >2.9 >2.8 >2.7 >2.6 >2.5 >2.4
Over heat protection
YES YES YES YES YES YES YES YES YES YES YES YES YES
Rated power(W)
30 31.2 32.2 33 33.6 34 35.1 36.1 37 37.8 38.5 39.1 39.6
Switch frequency(KHZ)
132 132 132 132 132 132 132 132 132 132 132 132 132
Insulation class
II II II II II II II II II II II II II
Consumes(W)
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
Efficiency(%)
>
>>
>83.7
>
>>
>83.9
>
>>
>84.1
>
>>
>84.3
>
>>
>84.4
>
>>
>84.5
>
>>
>84.7
>
>>
>84.8
>
>>
>85 >
>>
>85.1
>
>>
>85.2
>
>>
>85.3
>
>>
>85.4
Efficiency Level
V V V V V V V V V V V V V
Note: ADJ . output voltage procedure
1. Power off
2. Select suitable output voltage form 12V to 24V by changeable slot.
3. Connect to Load
4. Power ON