Datasheet
AM 0055H (09262H) SWITCHING ADAPTOR SPECIFICATIONS 
Ver: 1            Date: 2011-05-28                             
AMPLUS
                                      AM09262              Page 
5
1
RD
1
SPECIFICATION
12. 
SAFETY STANDARD 
To meet ETL-UL1950,CETL-C22.2 NO.950, GS-DIN EN60950 
AS/NZS 4665.1 : 2005, EuP 2005/32/EC 
13. 
RFI EMISSION 
EN55022: 2006+A1 
EN61000-3-2: 2000 
EN61000-3-3: 1995+A1 
EN55024: 1998+A1+A2 
FCC PART 15 
14. 
OUTPUT RATED & ELECTRICAL SPECIFICATIONS 
RATED OUTPUT (V) 
12  13  14  15  16  17  18  19  20  21  22  23  24 
Rated current(A) 
2.5  2.4  2.3  2.2  2.1  2.0  1.95  1.9  1.85  1.8  1.75  1.7  1.65 
Max. output voltage(V) 
12.5  13.5  14.5  15.5  16.5  17.5  18.5  19.5  20.5  21.5  22.5  23.5  24.5 
Min. output voltage(V) 
11.5  12.5  13.5  14.5  15.5  16.5  17.5  18.5  19.5  20.5  21.5  22.4  23.4 
Ripple & Noise(mV) 
<150  <150  <150  <150  <150  <150  <150  <150  <150  <150  <150  <150  <150 
Over load current(A) 
>4.0  >3.7  >3.5  >3.4  >3.2  >3.1  >3.0  >2.9  >2.8  >2.7  >2.6  >2.5  >2.4 
Over heat protection 
YES  YES  YES  YES  YES  YES  YES  YES  YES  YES  YES  YES  YES 
Rated power(W) 
30  31.2  32.2  33  33.6  34  35.1  36.1  37  37.8  38.5  39.1  39.6 
Switch frequency(KHZ) 
132  132  132  132  132  132  132  132  132  132  132  132  132 
Insulation class 
II  II  II  II  II  II  II  II  II  II  II  II  II 
Consumes(W) 
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
<0.3W
Efficiency(%) 
>
>>
>83.7
>
>>
>83.9
>
>>
>84.1
>
>>
>84.3
>
>>
>84.4
>
>>
>84.5
>
>>
>84.7
>
>>
>84.8
>
>>
>85  >
>>
>85.1
>
>>
>85.2
>
>>
>85.3
>
>>
>85.4
Efficiency  Level 
V  V  V  V  V  V  V  V  V  V  V  V  V 
Note: ADJ . output voltage procedure 
1.  Power off 
2.  Select suitable output voltage form 12V to 24V by changeable slot. 
3.  Connect to Load 
4.  Power ON 