Datasheet

AM 0055H (09262H) SWITCHING ADAPTOR SPECIFICATIONS
Ver: 1 Date: 2011-05-28
AMPLUS
AM09262 Page
4
1
RD
1
SPECIFICATION
The S.M.P.S should not be fired or emitted smoke by protection when the circuit is short.
The S.M.P.S can be changeable output voltage by changeable slot.
6.
DC INSULATION RESISTANCE
Input – Output : 50Mminimum (at 500VDC)
Input – Body metal : 50Mminimum (at 500VDC)
7.
DIELECTRIC WITHSTAND - VOLTAGE
Input – Output : 3750VAC minimum (2s)
Input – Body metal : 3750VAC minimum (2s)
8.
MAIN FUSE
Input fuse is 3.15A 250V
9.
INRUSH CURRENT
Peak inrush current shall be limited to 30A for a cold start
10.
TIME SEQUENCE
Time sequence should be satisfied to power ON/OFF, restart in
power failure
AC switch at ON/OFF
11.
EFFICIENCY
The efficiency of the S.M.P.S must be satisfied the minimum 83.7%.
100%V
95%V
95%V
20m S 1 .0S
AC input
DC onput