Datasheet
AM 0055H (09262H) SWITCHING ADAPTOR SPECIFICATIONS 
Ver: 1            Date: 2011-05-28                             
AMPLUS
                                      AM09262              Page 
4
1
RD
1
SPECIFICATION
The S.M.P.S should not be fired or emitted smoke by protection when the circuit is short. 
The S.M.P.S can be changeable output voltage by changeable slot. 
6. 
DC INSULATION RESISTANCE 
Input – Output : 50MΩminimum (at    500VDC) 
Input – Body metal : 50MΩminimum (at    500VDC) 
7. 
DIELECTRIC WITHSTAND - VOLTAGE 
Input – Output : 3750VAC minimum (2s) 
Input – Body metal : 3750VAC minimum (2s) 
8. 
MAIN FUSE 
Input fuse is 3.15A 250V 
9. 
INRUSH CURRENT 
Peak inrush current shall be limited to 30A for a cold start 
10. 
TIME SEQUENCE 
Time sequence should be satisfied to power ON/OFF, restart in   
power failure 
AC switch at ON/OFF 
11. 
EFFICIENCY 
The efficiency of the S.M.P.S must be satisfied the minimum 83.7%. 
100%V 
95%V
95%V
≧20m S ≦1 .0S 
AC input 
DC onput 