Datasheet

Chassis Mount, Clamp Construction Page 2 of 6
Chassis Mount, Clamp Construction
230 or 115/230 VAC Primary transformer, 6VA - 200VA
Chassis mounting low voltage mains transformers designed according to the following specifications.
Specifications:
Power:
Frequency:
Primary:
Secondary:
Isolation:
Temp. class:
Approvals:
50 - 1000 VA
50/60 Hz
230 or 115/230 VAC
2 parallel (see list below)
4 kV RMS
A (105°)
BS3535 and EN 60 742
Chassis mounting low voltage mains transformers with a single 230 VAC or twin 115 VAC
50/60Hz primary winding. The two independent secondary windings may be connected in
series or parallel to give a wide range of output voltage and current options.
Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps
Solder tag terminations
Optional terminal shrouds
100% electrical and flash tested
Selection guide
rated
regulation
dimensions
fixing centers
wt.
VA % typ. L. W.
H.
kg
6 25 45 40
37
53.5x4BA 0.2
12 15 59 50
50
70x2BA 0.4
20 12 59 57
50
70x2BA 0.55
50 10 79 62
65
92x2BA 1.0
75 10 79 75
65
54x54x4BA 1.5
100 10 89 68
75
57x43.5x2BA
1.6
150 10 100
82
82
72x60xM5 2.0
200 7 100
92
82
72x70xM5 2.8