Manual
SK 180E Manual for frequency inverters     
174  Pre-series version  BU 0180 GB-0914 
9.8.2 87Hz characteristic curve (only 400 V devices) 
( Variation 01:17:00) 
The 87 Hz characteristic represents an extension of 
the speed  adjustment  range  with a  constant  motor 
nominal torque. The following points must be met for 
realisation: 
  Motor  delta  connection  with  a  motor  winding 
for 230/400 V 
  Frequency  inverter  with  an  operating  voltage 
3~400 V 
  Output current of  frequency  inverter must  be 
greater than the delta current of the motor used 
(ref. value   frequency inverter power    3 x 
motor power) 
In this configuration, the motor used has a rated operating point at 230 V/5 0Hz and an extended operating 
point at 400  V/ 87Hz. This increases the  power of the drive  by the factor  3. The nominal torque  of the 
motor  remains constant  up  to a  frequency of  87 Hz.  Operation  of  a  230  V  winding  with  400  V  is totally 
uncritical as the insulation is designed for test voltages of > 1000 V. 
The following data refer to a 230/400 V motor winding. They apply for IE1 or IE2 motors. It should be noted that 
these details may deviate slightly, as motors are subject to certain manufacturing tolerances. It is recommended 
that the resistance of the connected motor is measured by the frequency inverter (P208 / P220). 
Frequency inverter type 
Parameterisation data of frequency inverter 
F
N
 [Hz] 
n
N
[min
-1
] 
I
N 
[A] 
U
N
 [V] 
P
N
 [kW] 
cos  
Circuit 
R
St 
[] 
IE1 Motors 
SK…63S/4  SK 1x0E-250-340-B 
50 
1335 
0.95 
230 
0.12 
0.64 
Delta 
68.00 
SK…63L/4  SK 1x0E-370-340-B 
50 
1360 
1.18 
230 
0.18 
0.64 
Delta 
47.37 
SK…71S/4  SK 1x0E-550-340-B 
50 
1365 
1.30 
230 
0.25 
0.79 
Delta 
39.90 
SK…71L/4  SK 1x0E-750-340-B 
50 
1380 
1.89 
230 
0.37 
0.71 
Delta 
22.85 
SK…80S/4  SK 1x0E-111-340-B 
50 
1385 
2.62 
230 
0.55 
0.75 
Delta 
15.79 
SK…80L/4  SK 1x0E-151-340-B 
50 
1395 
3.52 
230 
0.75 
0.75 
Delta 
10.49 
SK…90S/4  SK 1x0E-221-340-B 
50 
1410 
4.78 
230 
1.1 
0.76 
Delta 
6.41 
IE2 Motor 
SK…80SH/4   TI 4 - SK 1x0E-110-340-B 
50 
1415 
2.39 
230 
0.55 
0.70 
Delta 
9.34 
SK…80LH/4    TI 4 - SK 1x0E-151-340-B 
50 
1410 
3.12 
230 
0.75 
0.75 
Delta 
6.30 
SK…90SH/4   TI 4 - SK 1x0E-221-340-B 
50 
1430 
4.26 
230 
1.1 
0.80 
Delta 
4.96 
Frequency inverter type 
Performance data at rated point* 
P
B
 [kW] 
n
B
 [min
-1
] 
M
B 
[Nm] 
SK…63S/4       SK 1x0E-250-340-B 
0.21 
2430 
0.80 
SK…63L/4       SK 1x0E-370-340-B 
0.31 
2455 
1.20 
SK…71S/4       SK 1x0E-550-340-B 
0.43 
2460 
1.65 
SK…71L/4       SK 1x0E-750-340-B 
0.64 
2475 
2.49 
SK…80S(H)/4   SK 1x0E-111-340-B 
0.95 
2480 (2510) 
3.67 (3.6) 
SK…80L(H)/4    SK 1x0E-151-340-B 
1.3 
2490 (2505) 
5.01 (4.9) 
SK…90S(H)/4   SK 1x0E-221-340-B 
1.9 
2505 (2525) 
7.32 (7.2) 
* Values in brackets apply for IE2 motors 
87 Hz characteristic curve (4-pole motor)
0
0,2
0,4
0,6
0,8
1
1,2
0 10 20 30 40 50 60 70 80 90 100
Frequenz / Hz
M/Mn
  M/M
N 
  P/P
N
0  1445  2890 
Frequency 
[Hz] 
Speed 
[1/min] 