User guide
SK 105E…175E Motor Starter Manual     
72  Pre-series version  BU 0135 GB-2713 
5.1.6  Information 
Parameter 
{ Factory setting } 
Setting value / Description / Note 
READ  RAM 
READ / 
FLASH 
FLASH 
P700  [-01] 
  ... 
  [-03] 
Present op. status 
 (Present operating status)  
x       
0.0 ... 21.4  Display of current messages for the present operating status of the motor starter such as errors, 
warnings or the reason why switch-on is disabled. For details of messages see Section 6  
[-01] = Present fault, shows the currently active (unacknowledged) fault (Section 6.2). 
[-02] = Current warning, shows any current warning message (Section 6.3)  
[-03] = Reason for disabled starting, indicates the reason for an active start disable (Section 6.4). 
Note 
SimpleBox: with the Simplebox 
only warning messages and faults can be displayed. Display of 
the messages is encoded. For the description of the codes (warning/error numbers), please 
refer to the tables in Sections Error! Reference source not found.and 6.3 
ParameterBox: 
with the ParameterBox the messages are displayed in plain text.. In addition, 
the reason for a possible disabling of starting can also be displayed. 
P707  [-01] 
  ... 
  [-03] 
 Software version  
(Software version/ revision)  
x       
0.0 ... 9999.9 
This parameter shows the software and 
revision numbers in the motor starter. This 
can be sig
nificant when different motor 
starters are assigned the same settings. 
Array [-
03] provides information about any 
special versions of the hardware or 
software A zero stands for the standard 
version. 
[-01] = Software version, version number (V1.0) 
[-02] = Software revision, Revision number (R1) 
[-03] = Special version, of the hardware/ 
software (0.0) 
P708 
Digital input status 
(Status of digital input)  
x       
00000 ... 11111 (bin) 
or 
0000 ...007F (hex) 
Displays the stat
us of the digital inputs in binary/hexadecimal code. This display can be used to 
check the input signals. 
Bit 0 = Digital input 1 
Bit 1 = Digital input 2 
Bit 2 = Thermistor input  
Bit 3 = AS-i In Bit 0 
(only SK 145E…175E)
Bit 4 = AS-i In Bit 1 (only SK 145E…175E) 
Bit 5 = AS-i In Bit 2 (only SK 145E…175E) 
Bit 6
 = AS-i In Bit 3 (only SK 145E…175E)  
  Bits 7-4  Bits 3-0   
Minimum value 
0000 
0 
0000 
0 
Binary 
hex 
Maximum value 
0111 
7 
1111 
F 
Binary 
hex 
SimpleBox: The binary Bits are converted into a hexadecimal value and displayed. 