User guide
2 Assembly and installation 
BU 0135 GB-2713  Pre-series version  19 
2.1.3  Installation of the motor starter 
The housing cover must first be removed in order to make the electrical connections to the SK 1x5E. To do 
this, unscrew the 4 fastening screws, so that the housing cover can be removed upwards.  
After the electrical connections of the supply cables have been made, the housing cover can be replaced.  
To achieve the maximum protection class IP55/IP66, care must be taken that all the fastening screws of the 
housing cover are tightened diagonally, step-by-step and with the torques stated in the table below.  
For the cable gland of the connecting cable, appropriate screwed connections for cable cross-section must 
be used. 
Motor starter size  Screw size  Tightening torque 
Size I  M5 x 25  3.5Nm ± 20% 
Size II  M5 x 25  3.5Nm ± 20% 