Intelligent Drivesystems, Worldwide Services GB B1092 Operating and Assembly Instructions for 1 MA-7 Three-phase Motors for operation with Frequency Inverters BG 63 - 160
Contents 1. 2. General Information ................................................................................................................3 Description ..............................................................................................................................3 2.1 Field of application ....................................................................................................................3 2.2 Cooling ...................................................................
1. General information 2. Description 1. General information The applicable national, local and plant-specific regulations and requirements must be observed. Technical details may vary for special designs and constructions. In case of doubt it is urgently recommended that the manufacturer is contacted, giving details of the type and serial number (No. …. see rating plate), or have the maintenance work carried out by a service centre. 2.
3. Notes 3.2 Installation For vertical configuration, all available lifting lugs and if necessary lifting straps (DIN EN 14921:2000) and/or tie-down straps (DIN EN 12195-2:2001) must be used to stabilise the position. Attachments must not be used as lifting aids. After installation, screwed-on lifting lugs must be tightened or removed. For vertical installation with the shaft end pointing downwards, a protective cover for the fan cover is recommended, to prevent the entry of foreign bodies.
3. Notes For tightening torques of screw connections of the electrical connections and terminal board connections (except for the terminal bar) see Fig. 4. 3.6 Checking the insulation resistance Prior to the initial commissioning of the motor after a long period of storage or standstill (approx. 6 months) the insulation resistance of the windings must be checked. During and immediately after the measurements, the terminals have voltages which can be dangerous, and must not be touched.
4. Maintenance Safety measures Before starting any work on the motor or the device, but especially before opening the covers of active components, the motor must be isolated according to regulations. In addition to the main power circuits, any additional or auxiliary circuits must be taken into account. The usual "5 Safety Rules" e.g.
4. Maintenance General overhaul A general overhaul of the motor must be carried out every 5 years. For this the motor must be dismantled.
5. Motors with increased ignition protection, type "e" Ex e 5. Motors with increased ignition protection, type "e" Ex e 1MA Identification: CE 0102 II G Ex e lI T3 Attention Repairs must be carried out in or by authorised workshops. Repairs must be documented on the motor (e.g. additional plate). The increased hazard in areas endangered by explosions or fire damp requires particularly careful observation of the general safety and start-up information.
5. Motors with increased ignition protection, type "e" Ex e In the case of external sources of heat or cold, no additional measures are necessary if the temperatures of the attached components do not exceed the permissible temperatures listed in Table 3. The values in Table 3 apply for an ambient temperature of -20°C to +40°C with self-ventilation.
5. Motors with increased ignition protection, type "e" Ex e Shaft height Thread size Number 63 – 90 M16x1.5 1 M25x1.5 1 100 – 132 M32x1.5 4 160 M40x1.5 4 Table 1: Thread sizes in terminal box Shaft height Thread of screw for bonding cable 63 – 90 M4 100 – 112 M5 132 – 160 M6 Table 2: Bonding cable screw threads Number of pairs of poles 4-pole Maximum shaft temperature 75°C Maximum flange temperature 75°C Table 3: Maximum permissible heat and cold sources -10- B1092-GB www.
6. Drawing and list of replacement parts 6.1 List and drawings of replacement parts Replacement parts which can be supplied ex works Item no. Designation 1.00 AS bearing .40 Bearing cover .43 Shaft seal .58 Spring washer .60 Roller bearing .61 Spring strip for bearing cover hub (not always present) 3.00 .88 Rotor, complete Parallel key for fan 4.00 .07 .08 .18 .19 .20 .30 .31 Stator, complete Housing foot, right Housing foot, left Rating plate Screw Cover Contact bracket Earthing bracket 5.00 .03 .04 .
6. Drawing and list of replacement parts Standard components to be obtained commercially according to dimensions, materials and surfaces. 4.05 (see Fig. 3) 4.10 4.39 5.78 7.12 DIN EN ISO 70897090 (DIN 125) DIN 128 DIN 471 6.02 DIN 472 4.04 (see Fig. 3) DIN 580 1.49 4.11 4.39 5.19 5.49 5.79 5.89 5.91 5.94 6.29 7.49 3.38 DIN EN ISO 4762 (DIN 912) 5.52 5.53 5.96 1.60 6.
certified screw connection (5.1) For aluminium bearing covers (1.40 AH 90) a spring strip (1.61) is inserted in the hub (hook the bead into the groove). 6. Drawing and list of replacement parts Fig. 2 BG63…90L www.nord.
certified screw connection (5.1) For aluminium bearing covers (1.40/6.20) a spring strip (1.61/6.11) is inserted in the hub (hook the bead into the groove). 6. Drawing and list of replacement parts Fig. 2 BG 100…160L -14- B1092-GB www.nord.
6. Drawing and list of replacement parts e.g. outlet for cables and wires - at bottom Fig. 3, BD 100…160L, version with lateral configuration of upper section of terminal box (rotatable 4x90 degrees) 6.2 Tightening torques Tightening torques for terminal board connections Thread diameter M4 M5 M6 M8 M10 M12 M16 Tightening torque (Nm) min. 0.8 1.8 2.7 5.5 9.0 14.0 27.0 Tightening torque (Nm) max. 1.2 2.5 4.0 8.0 13.0 20.0 40.0 Fig.
6. Drawing and list of replacement parts 6.3 Cross sections which may be connected …25 mm2 …10 mm2 …25 mm2 …10 mm2 …25 mm2 For connection with a DIN fork terminal, the fork terminal must be angled downwards. Connection of a single conductor with retaining clip. Connection of two conductors of approximately the same diameter with retaining clip. Connection of a single conductor under the external earthing bracket. For connection with DIN fork terminal under the external earthing bracket. Fig.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3046 X for the three-phase motor, type 1MA7 063-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 0.3 0.8 1.1 0.36 Nm Power: 0.008 0.053 0.158 0.108 kW 80 200 400 400 V 0.33 0.48 0.58 0.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3046 X for the three-phase motor, type 1MA7 063-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3047 X for the three-phase motor, type 1MA7 073-4… Design values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 0.5 2.0 2.6 0.8 Nm Power: 0.005 0.128 0.356 0.224 kW Voltage: *) 40 200 400 400 V Current: 0.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3047 X for the three-phase motor, type 1MA7 073-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3048 X for the three-phase motor, type 1MA7 083-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 1.4 4.5 5.2 1.8 Nm Power: 0.015 0.295 0.75 0.531 kW Voltage: *) 40 200 400 400 V Current: 1.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3048 X for the three-phase motor, type 1MA7 083-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3049 X for the three-phase motor, type 1MA7 096-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 3.0 9.1 9.1 3.6 Nm Power: 0.034 0.604 1.34 1.08 kW Voltage: *) 40 200 400 400 V Current: 1.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3049 X for the three-phase motor, type 1MA7 096-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3050 X for the three-phase motor, type 1MA7 106-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 5 13.5 13.5 5.5 Nm Power: 0.061 0.937 2.0 1.67 kW Voltage: *) 40 200 400 400 V Current: 2.4 4.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3050 X for the three-phase motor, type 1MA7 106-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 02 of the EU Prototype Test Certificate PTB 07 ATEX 3050 X for the three-phase motor, type 1MA7 107-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 5 14 16.8 7.5 Nm Power: 0.065 0.99 2.5 2.2 kW Voltage: *) 40 200 400 400 V Current: 2.5 4.
7. Data Sheets Translated extract from Data Sheet 02 of the EU Prototype Test Certificate PTB 07 ATEX 3050 X for the three-phase motor, type 1MA7 107-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3051 X for the three-phase motor, type 1MA7 113-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 10.1 19 23.9 11 Nm Power: 0.123 1.38 3.57 3.23 kW Voltage: *) 40 200 400 400 V Current: 4.4 6.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3051 X for the three-phase motor, type 1MA7 113-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3052 X for the three-phase motor, type 1MA7 133-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 15 44 44 20.2 Nm Power: 0.218 3.28 6.83 6.18 kW Voltage: *) 40 200 400 400 V Current: 7.4 13.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3052 X for the three-phase motor, type 1MA7 133-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3053 X for the three-phase motor, type 1MA7 163-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 50 60 65.7 27 Nm Power: 0.672 4.48 10 8.244 kW Voltage: *) 53 200 400 400 V Current: 14 17.
7. Data Sheets Translated extract from Data Sheet 01 of the EU Prototype Test Certificate PTB 07 ATEX 3053 X for the three-phase motor, type 1MA7 163-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
7. Data Sheets Translated extract from Data Sheet 02 of the EU Prototype Test Certificate PTB 07 ATEX 3053 X for the three-phase motor, type 1MA7 166-4… Rated values and data This certificate applies for the following versions on condition that motors of this type only vary to an insignificant extent from the tested sample with regard to the electrical and thermal load: Star connection Torque: 62 88 88 35.5 Nm Power: 0.774 6.6 13.531 10.
7. Data Sheets Translated extract from Data Sheet 02 of the EU Prototype Test Certificate PTB 07 ATEX 3053 X for the three-phase motor, type 1MA7 166-4… Monitoring devices To prevent impermissible heating due to overload, the motors are monitored by connection to a device for direct temperature monitoring in combination with defined setting data of the inverter.
7.
8. Type Plates www.nord.
9. Declaration of Conformity -48- B1092-GB www.nord.
10. Addresses Getriebebau NORD national: North branch Hamburg / Schleswig-Holstein / Niedersachsen Sales office Bremen westliches Niedersachsen / Bremen West branch Köln / Koblenz / südl. Nordrhein-Westfalen / Ruhrgebiet / Düsseldorf Sales Office Butzbach Hessen / Frankfurt / Wiesbaden / Darmstadt East branch Sachsen / südl. Sachsen-Anhalt / Thüringen Sales Office Berlin Berlin / Brandenburg Mecklenb.-Vorpommern / nördl. Sachsen-Anhalt South branch Stuttgart / Baden-Würtemberg / Saarland / südl.
10. Addresses Getriebebau NORD International: AT Getriebebau NORD GmbH Deggendorfstraße 8, A-4030 Linz Tel.: +43-732-31 89 20 Fax: +43-732-31 89 20-85 info@nord-at.com AUS NORD Drivesystems 18 Stoney Way 3030 Derrimut Vic, Australia Tel: +61 (0) 488 588 200 mark.alexander@nord.com MX NORD Gear corporation Av. Lázaro Cárdenas 1007 Pte, San Pedro Garza Caría, N.L. MX – 66266 Mexico, C.P. Tel.: +52-81-82 20 91 65 Fax: +52-81-82 20 90 44 HGonzales@nord-mx.com NL NORD Aandrijvingen Nederland B.V.
Getriebebau NORD GmbH & Co. KG Rudolf-Diesel-Str. 1 D - 22941 Bargteheide Fon +49 (0) 4532 / 401 - 0 Fax +49 (0) 4532 / 401 - 253 info@nord.com www.nord.com DRIVESYSTEMS Mat.-Nr.