Datasheet
Sida 1(3)
Customer: ELFA AB
yellow green
U = 110V 200 VA
S1 Uo = 117,3V
2A
red
230V P1
48-60H
z
brown
U = 110V 200 VA
S2 Uo = 117,3V
2A
yello
w
blue
Classification
Protection against electrical shock: Isolating Transformer
Protection index: IP00
Protection against short-circuit and abnormal use: Non-short-circuit proof
Time of operation: Continously
Intended use: Incorporated
Ambient temperature / Material Classification: Ta40/E
Assembling: Centre potted with a drilled centre hole with an insert nut type M8.
A rubber pad is glued at the bottom of the transformer.
Dimensions: OD = 140 mm
H = 60 mm
Terminations:
Prim: Multistranded Wire Style 3266. Awg 18
Sec: Solid Copper insulated with tubes of Natvar.
Label on the paper box.
Transf.No.
ELFA P/N:
Label on transformer.
Transf.No.
Prim. 230V 48-60Hz ye-ye IP00 ta40/E
400
VA
L = 200mm
External fuse:
External fuse:
Sec. 2x 110V
Toroid International AB
AA-98045
56-138-56
Toroid International AB
AA-98045
gn-re/bn-bu
AA-98045
1999-04-14 / ts
Transf. No.
L = 200mm
56-138-56
Designed: