User guide
5
3.2  Ultrasonic Sensor Serial Number Arrangement 
When installing the UC5 sensors, start with the smallest serial number on the left-hand side, 
and proceed to the largest serial number on the right hand side. Each UC5 sensor has a serial 
number stamped on the sensor housing. 
Apply a light coating of the supplied Permatex Anti-seize grease to all threaded 
parts upon installation. 
Figure 3: Sensor Serial Number Arrangement 
  Only the components shown in black are included in this kit. 
A problem can arise if a sensor is not mounted correctly. It is possible for the 
sensor to read off of the boom instead of the ground. This may only become 
apparent once the control system is switched from soil to crop mode. 
Also be careful that the sensor bracket does not collide with any other part of the 
boom when the boom is folded to transport position. If possible, mount the sensor 
brackets while the booms are folded to ensure they will not cause interference. 