Spray Height Controller Sixth Sensor Installation Manual Improving the competitiveness of Industry and Agriculture through Precision Measurement
Printed in Canada Copyright 2005-08 by NORAC Systems International Inc. Reorder P/N: 4470BC+INST Rev A (Sixth Sensor Option) NOTICE NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.
TABLE OF CONTENTS 1 INTRODUCTION .................................................................................................................................................. 1 2 GENERAL SYSTEM DESCRIPTION ................................................................................................................... 2 3 PARTS LISTS..........................................................................................................................................................
1 INTRODUCTION This kit provides the necessary hydraulic and electrical parts that will allow your sprayer to provide ACTIVE boom roll control. These parts integrate into your existing NORAC UC4+ Sprayer Height Control System for minimal setup of this feature. Every standard UC4+ Sprayer Height Control System ships with a Main Roll Sensor in the center of the booms. With your roll control option installed, this sensor will now do double-duty and be able to detect the pivot position of your booms.
2 GENERAL SYSTEM DESCRIPTION Figure 1 depicts the general system layout of the UC4+ Spray Height Control system. Figure 1 – System Components and General Location NOTICE: Every effort has been made to ensure the accuracy of the information contained in this manual. All parts supplied are selected specially to fit the sprayer to facilitate a complete installation. However, NORAC cannot guarantee all parts fit as intended due to the variations of the sprayer by the manufacturer.
3 PARTS LISTS The parts that come with your UC4+ Spray Height Control System are listed in Table 1. The item number on the left side of this table references each part. Please ensure that all parts in your kit are present before proceeding with your installation.
The parts that come with your UC4+ Spray Height Control are shown below in their general installation configuration.
4 INSTALLATION PROCEDURE 1. Assemble the main lift sensor bracket (B13) as shown in Figure 3. Sensor Mounting Collar 6. Disconnect the connector and insert cable C71 between the two connectors. Reconnect all the AMP connectors. Bracket Tube Sensor Mounting Tab 5. Locate the 4 pin AMP connection on the sensor branch cable (cable routed to the sensors). Bracket Base Figure 3 – Main Lift Sensor Bracket 2. The bracket can then be mounted to the lowest frame member on the center section of the sprayer.
www.norac.ca Canada NORAC Systems International Inc. CALL TOLL FREE: 1-800-667-3921 (306)664-6711 SHIPPING ADDRESS: 3702 Kinnear Place Saskatoon, SK S7P 0A6 United States NORAC, Inc.