Manual
Bank
Item name RAM address EEPROM address RAM EEPROM
Decimal point
Remarks
Decimal
Hexadecimal
Decimal
Hexadecimal
Read Write Read Write
information
DO Control output 2 Polarity 5621 15F5 22005 55F5 —
Assignment Control output 2 Latch 5622 15F6 22006 55F6 —
Event output 1 Operation type 5623 15F7 22007 55F7 —
E
vent output
1 Output assign A
5624 15F8 22008 55F8 —
E
vent output
1 Output assign B
5625 15F9 22009 55F9 —
E
vent output
1 Output assign C
5626 15FA 22010 55FA —
E
vent output
1 Output assign D
5627 15FB 22011 55FB —
Event output 1 Polarity A 5628 15FC 22012 55FC —
Event output 1 Polarity B 5629 15FD 22013 55FD —
Event output 1 Polarity C 5630 15FE 22014 55FE —
Event output 1 Polarity D 5631 15FF 22015 55FF —
Event output 1 Polarity 5632 1600 22016 5600 —
Event output 1 Latch 5633 1601 22017 5601 —
Event output 2 Operation type 5634 1602 22018 5602 —
E
vent output
2 Output assign A
5635 1603 22019 5603 —
E
vent output
2 Output assign B
5636 1604 22020 5604 —
E
vent output
2 Output assign C
5637 1605 22021 5605 —
E
vent output
2 Output assign D
5638 1606 22022 5606 —
Event output 2 Polarity A 5639 1607 22023 5607 —
Event output 2 Polarity B 5640 1608 22024 5608 —
Event output 2 Polarity C 5641 1609 22025 5609 —
Event output 2 Polarity D 5642 160A 22026 560A —
Event output 2 Polarity 5643 160B 22027 560B —
Event output 2 Latch 5644 160C 22028 560C —
Event output 3 Operation type 5645 160D 22029 560D —
E
vent output
3 Output assign A
5646 160E 22030 560E —
E
vent output
3 Output assign B
5647 160F 22031 560F —
E
vent output
3 Output assign C
5648 1610 22032 5610 —
E
vent output
3 Output assign D
5649 1611 22033 5611 —
Event output 3 Polarity A 5650 1612 22034 5612 —
Event output 3 Polarity B 5651 1613 22035 5613 —
Event output 3 Polarity C 5652 1614 22036 5614 —
Event output 3 Polarity D 5653 1615 22037 5615 —
Event output 3 Polarity 5654 1616 22038 5616 —
Event output 3 Latch 5655 1617 22039 5617 —
Event Internal Event 1 Operation type 5801 16A9 22185 56A9 —
Configuration
Internal Event 1 Direct/Reverse 5802 16AA 22186 56AA —
Internal Event 1 Standby 5803 16AB 22187 56AB —
Internal Event 1 state at READY 5804 16AC 22188 56AC —
(Reserved for future extension.) 5805 16AD 22189 56AD ∆∆∆∆ —
Internal Event 1 Controller alarm OR 5806 16AE 22190 56AE —
Internal Event 1 Special OFF setup 5807 16AF 22191 56AF —
Internal Event 1 Delay unit
5808 16B0 22192 56B0 —
(Reserved for future extension.) 5809 16B1 22193 56B1 ∆∆∆∆ —
Internal Event 2 Operation type 5810 16B2 22194 56B2 —
Internal Event 2 Direct/Reverse 5811 16B3 22195 56B3 —
Internal Event 2 Standby 5812 16B4 22196 56B4 —
Internal Event 2 state at READY 5813 16B5 22197 56B5 —
(Reserved for future extension.) 5814 16B6 22198 56B6 ∆∆∆∆ —
Internal Event 2 Controller alarm OR 5815 16B7 22199 56B7 —
9-5
Chapter 9. LIST OF COMMUNICATION DATA