Instruction Manual

88
Visit our Web Site www.n-c.com
IntellIsys AdAptIve pressure Controllers
IQ+ OP-LIT 9/08
TABLE 3.2 BURIED BOX CONTROLLERS (SLAVE)
POWER (XLR) SERVICE PORT VALVE
PIN FUNCTION PIN FUNCTION PIN SIGNAL ASSIGNMENT
1 +240VDC Power Input 1 Authorized Technicians
Only
1 Drive A +
2 Power Return 2 Authorized Technicians
Only
2 Drive A -
3 Drain
1
3 Authorized Technicians
Only
3 Drive B -
4 N-C Net Hi
2
4 Drive B +
5 NC- Net Low
2
5 Sense B -
6 Sense B +
7 Sense A -
8 Sense A +
9 Reserved
10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 Reserved
15 Reserved
O P E N
C L O S E
Ctrl
Fault
1
3
5
7
9
SLAVE ID
POWER
Net
SVC
PORT
IQ+ SERIES
P O W ER
VALVE
FIGURE 3.2 BURIED BOX CONTROLLER (SLAVE)
3.2 - Slave Buried Box Controllers
1
Connect to Earth Ground at power supply
2
N-C Net is a proprietary communication protocol. Do not connect these pins to anything other than approved Nor-Cal items.