Instruction Manual
29
Call toll free 800-824-4166 or 530-842-4457 • FAX 530-842-9130
IntellIsys AdAptIve pressure Controllers
IQ+ OP-LIT 9/08
Instance ID 2 (position control)
NOTE: There is no subclass
for instance 2
TABLE 8.11.2 – S-SINGLE STAGE CONTROLLER OBJECT ATTRIBUTES; INSTANCE 2
ATTRIBUTE ID HEX SERVICE ID HEX NAME FORMAT VALUE
3 0E (get) 10 (set) Data type USINT
C3h = INT (default)
CAh = Real
4 0E (get) 10 (set) Data units UINT
1001h = Counts (default
1007h = Percent
1703h = Degrees
5 0E (get) 10 (set) Control Mode USINT See table 8.11.3
6 10 (set) Setpoint UINT Specified by data type
7 0E (get)
Process
variable
(Position)
Specified by
data type
Analog output value
Linked to S-Analog Sensor
Object, instance 3
9 OE (get) 10 (set)
Control
variable
Specified by S-
Analog Actuator
Object data type
Drive signal output
Linked to S-Analog
Actuator Object, instance 1
0000h - 7FFFh
0A 0E (get) Status BYTE See table 8.11.4
11 OE (get) 10 (set) Safe State USINT See table 8.11.5
TABLE 8.11.4 – S-SINGLE
STAGE CONTROLLER OBJECT
STATUS BITMAP
BIT DEFINITION
0
Alarm exception
0 = cleared, 1 = set
1
Warning exception
0 = cleared, 1 = set
2-7
Reserved
8.11 - S-Single Stage Controller Object (continued)
TABLE 8.11.3 – S-STAGE CONTROLLER
OBJECT CONTROL MODE VALUE
ATTRIBUTE
VALUE
ST
ATE
0
Normal
1
Closed
2
Open
3
Hold
4
Safe State (Closed)
5-63
Reserved
TABLE 8.11.5 – S-SINGLE STAGE
CONTROLLER OBJECT SAFE STATE VALUE
ATTRIBUTE
VALUE
ST
ATE
0
Closed
1
Open
2
Hold (Default)
3
Safe Value - Closed
4-63
Reserved