User Manual
1313
Visit our Web Site www.n-c.com
IntellIsys softshut
TM
Gate ValVe Models
TSS-OP-LIT 08/11
APPENDIX I - Summary Valve and Controller Connection Information
Controller Connection Diagrams Figures A-1
CAUTION: Do not connect cables to the valve when the controller is under power.
Motor Drive
For valves fitted with a motor-drive unit, connect a Nor-Cal TBV-CRD series valve cable between the motor drive and the buried-box controller.
IQA
For valves fitted with IQA controllers, first confirm that the DIPswitch settings are correct for your serial communications
1
, and then connect the
appropriate cables for Gauges, Auxiliary, and Analog/TTL
2
.
IQD
For valves fitted with IQD controllers, first confirm that the rotary DIPswitch settings are correct for your DeviceNet settings
1
, and then connect
the appropriate cables for Gauges, Auxiliary, Analog/TTL and/or a DeviceNet cable
2
.
1
IQ series DIPswitches are factory-set to default positions. Consult the IQ manual for detailed information on these settings.
2
Refer to the following section for detailed information on cabling requirements and pin-outs for IQ series accessory ports.