Owner manual

3232
Visit our Web Site www.n-c.com
IntellIsys AdAptIve pressure Controllers
APC-OP-LIT 1/12
9.12 - Selection Object
Class ID 2E hex
Instance ID 1 (setpoint)
TABLE 9.12.2 SELECTION OBJECT ATTRIBUTES; INSTANCE 2
ATTRIBUTE ID HEX ACCESS CODE NAME FORMAT VALUE
1 0E (get)
Source index
USINT
Value of instance 1 attribute 5
2 0E (get)
Number of sources
USINT
02
3 0E (get)
Source path length
UINT
00 06
4 0E (get)
Source list
EPATH
20/33/24/01/30/09
controller, process variable, CV
20/33/24/02/30/09
controller, valve position, CV
5 0E (get)
Destination index
USINT
01
6 0E (get)
Number of destinations
USINT
01
7 0E (get)
Destination path length
UINT
00 06
8 0E (get)
Destination list
EPATH
20/32/24/01/30/06
analog act, value
9 0E (get)
Source data value
Data type
Control variable (TBD)
A 0E (get)
Destination data value
Data type
Control variable (TBD)
B 0E (get)
Status
USINT
00
Attribute 5 determines
the selection between
pressure control or valve
control (1 for pressure
control, 2 for position
control), default is 1
after reset.
A change on attribute 5
only becomes effective
once a new setpoint is
sent (attribute 9)
When in pressure
control (destinationindex =1)
writing a new setpoint is immediately
tasking the controller to regulate to the designated pressure
When in position control (destination index=2) writing
a new setpoint will directly affect the valve position
Instance ID 2 (control signal)
NOTE: This object is static. The
only changing variable is the value
of attribute 4 that is linked to
instance 1 attribute 5.
TABLE 9.12.1 SELECTION OBJECT ATTRIBUTES; INSTANCE 1
ATTRIBUTE ID HEX ACCESS CODE NAME FORMAT VALUE
1 0E (get)
Source index
USINT
0
2 0E (get)
Number of sources
USINT
0
3 0E (get)
Source path length
UINT
0
4 0E (get)
Source list
EPATH
0 (USINT)
5 0E (get) 10 (set)
Destination index
USINT
01 or 02 default to 1 after reset
6 0E (get)
Number of destinations
USINT
02
7 0E (get)
Destination path length
UINT
00 06
8 0E (get)
Destination list
EPATH
20/33/24/01/30/06
controller, process variable, SP
20/33/24/02/30/06
controller, valve position, SP
9 0E (get) 10 (set)
Source data value
Data type
0% = 0000h, 100%=7FFFh
B 0E (get)
Status
USINT
00