User's Manual
57
Note: In 4WS or Thr/Brake mode the settings on this screen (End Points, Dual Rate, Trim,
Reverse, Type, and Servo Speed) still take effect. However, the Expo setting from the master
channel is also used. For Thr/Brake mode, Auto Start, Idle Up, and ABS also apply.
Channel 3 / 4 Servo Speed
Input/Throttle Speed determines the percentage of full
speed that is applied to the throttle movements that are
above the throttle trigger setting. 100 is maximum servo
movement rate. 1 is minimum rate. Default is 100 (full
speed).
Return/Brake Speed determines the percentage of full
speed that is applied to braking movements that are
above the trigger setting. 100 is maximum servo
movement rate. 1 is minimum rate. Default is 100 (full
speed).
Trigger sets the minimum amount of control input before
the speed limiter becomes active. At 0%, limiting is
always active (input is always >= 0%). At 50%, limiting
is only active if the throttle is on half way or more.
Brake Trigger sets the minimum amount of control input
before the speed limiter becomes active. At 0%, limiting
is always active (input is always >= 0%). At 50%,
limiting is only active if the brake is on half way or more.
The parameters of this function operate differently depending on which mode CH3/CH4 is
currently set for. (See Channel 3 and Channel 4 Servo Mode above).
Shift Servo mode set for 4WS Shift Servo mode set for Thr/Brake
Input/Throttle Speed acts as Input Speed
Return/Brake Speed acts as Return Speed
Trigger acts as Trigger
Brake Trigger is not used
Input/Throttle Speed is Throttle Speed
Return/Brake Speed acts as Brake Speed
Trigger acts as Throttle Trigger
Brake Trigger acts as Brake Trigger