Users Manual
Proprietary Information Page 2 of 3 Maxwise Group
Power-on
on 2s then off
Standby
LED off
Charging
LED on
Charging full
LED on
b) Alarm type
Alarm type
Led
Over-temperature/Low-temperature
Flashing LED
FOD
Flashing LED
Over voltage
Flashing LED
Under voltage
Flashing LED
Other
Flashing LED
C. Protection Requirements
NO.
Item
product qualification
a
Input Low-voltage protection
4.3±0.2V
b
Input Over-voltage protection
17±0.5V
c
Input Over-current protection
≥2A
d
Over-temperature protection
-10℃>℃<60℃
5.5 FOD (Foreign object detection)
The device has FOD function. When a metal foreign object is detected, enters the FOD mode, the
pure red LED flashes, 1 time/sec; When the metal foreign object is removed, the device exits FOD
mode and enters standby mode.
D. Environment Requirements
a) Operation temperature and relative Humidity.
-10℃ to +25℃;10%RH to 85%RH。
b) Storage temperature and relative Humidity.
-20℃ to +80℃;5%RH to 95%RH。