9. Finally read calibration parameter by selecting Read calibration value and press Send. (The purpose
of this step is to check that the set Parameter value has been written on EEPROM).
10. Alignment value should be according to following table:
Frequency Alignment value Tolerance
474 14 +/- 15
610 136 +/- 15
746 225 +/- 15
11. Finally measure RSSI values with Test set up – Option 2 with Rohde & Schwartz Shielding box.
RM-100