User Guide
5. Press the start button (see picture below).
6. Monitor the RSSI value in the Tuning Lock Summary field (see figure).
7. CW test result -> RSSI reading -> The RSSI value should be -69 dBm (±3 dBm).
Figure 84 Phoenix DVB-H testing window
Note: CW test result -> RSSI reading (“Signal Quality” feature is not needed).
8. Run DVB-H RX Test also with frequencies 610 MHz and 746 MHz according to following table.
Table 17 Setup and target test values (test option 1)
Frequency Signal level RSSI value Tolerance
474 -30 dBm -69 dBm +/-3 dBm
610 -30 dBm -56 dBm +/-3 dBm
746 -30 dBm -42 dBm +/-3 dBm
Note: Frequency in the table is typed in DVB-H Test/Frequency field. Set signal generator frequency always 1 MHz higher.
RM-100
Nokia Customer Care TV troubleshooting
Page 9 –8 COMPANY CONFIDENTIAL Issue 2
Copyright © 2007 Nokia. All rights reserved.