User Guide

Description Parameter Min Typ Max Unit Notes
Differential
voltage
swing
VOD 100 150 200 mV -2
Operating
frequency
fCLK 1 200 MHz SW controls
frequency
Differential
rise and fall
time
300 800 ps -3
Note:
Common mode voltage is a mean value of high and low states of one single-ended signal.
Differential voltage swing is differential amplitude between signals of differential pair.
Differential transitions should be only measured with good equipment (bandwith > 1GHz),
otherwise results will seem too slow.
Table 27 Unagi Camera supply voltage characteristics
Description Parameter Min Typ Max Unit
Camera analog
voltage
VDD 2.6 2.8 2.9 V
Camera digital
voltage
VDDI 1.4 1.5 1.6V V
Table 28 Unagi Camera control IF electrical characteristics
Description Parameter Min Typ Max Unit Notes
ExtClk VIH square
wave
0.8 x VDD - VDD V High-level
input
voltage
ExtClk VIL square
wave
0 - 0.54 V Low-level
input
voltage
ExtClk p-p
sinusoidal
wave
0.5 - 1.2 V Sinusoidal
mode
voltage
swing
ExtClk Frequency 9.6 MHz SW
controlled
frequency
SDA, SCL VIH 0.7 x VDD 1.8 VDD V High-level
input
voltage
SDA, SCL VIL 0 - 0.54 V Low-level
input
voltage
RM-42
System Module Nokia Customer Care
9241872 (Issue 1) Company Confidential Page 9–43
Copyright ©2005 Nokia. All Rights Reserved.