User Guide

Self test limits
Values in LSB
4605957 (ST, LIS3LV02DQ)
2.5V
x=(min 180, max 320)
y=(min 180, max 320)
z=(min 80, max 250)
2.8V, not evaluated
4605983 (ADI, AD22340)
2.5V not evaluated
2.8V
x=(min 15, max 30)
y=(min 15, max 30)
z=(min 3, max 15)
4605987 (ST, LIS302DL)
2.5V not evaluated
2.8V
x=(min 3, max 16), unsigned
y=(min 3, max 16), unsigned
z=(min 3, max 16), unsigned
Magnetometer troubleshooting
Equipment
Non-magnetic, horizontal table
nearest ferromagnetic part, distance more than 50 cm
Traditional needle type compass for reference
Rotating platform (sheet of wood or plastic)
PC with Phoenix
Preparation of phone
Set the rotating platform to the table
Set the phone and reference compass to the rotating platform
Connect the phone to the PC and start Phoenix
Tests
General troubleshooting test
Self-test (ST)
Azimuth check test
RM-484; RM-485; RM-486
BB Troubleshooting
Page 3 –30 COMPANY CONFIDENTIAL Issue 1